The air pressure transmitter PAM 1-series is used for measuring differential pressure, volume flow in air, above-atmospheric or below-atmospheric.
Part Number: PAM 1xxx
Manufacturer:
0Types Available
Back to Previous Page
Product Files

Description Air Pressure Transmitter PAM 1-series

The air pressure transmitter PAM 1-series is used for measuring differential pressure, volume flow in air, above-atmospheric or below-atmospheric.

Applications for air pressure transmitter PAM 1-series are in a clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for monitoring filters, for level measurement or for triggering frequency converters.

Media measured with air pressure transmitter PAM 1-series are air (non-precipitating), or other gaseous non-aggressive, non-combustible media.

PAM 1-series air pressure transmitter is equipped with 4 to 8 pcs DIP switchable measuring pressure ranges and 2 pcs DIP switchable output signals 0-10 Vdc or 4-20 mA.

The air pressure transmitter PAM 1-series can be supplied with or without LCD display.

The piezo-resistive measuring element for air pressure transmitter PAM 1-series is temperature- compensated and guarantees a high degree of reliability and accuracy.

The PAM 1-series air pressure transmitter has a pushbutton for manual zero point calibration and an adjustable offset.

The air pressure transmitter PAM 1-series is supplied including duct fixing kit (2 plastic tubes with integrated mounting plate, 2 meters PVC hose and 4 screws).

The PAM 1-series air pressure transmitter has high ingress protection IP67


4 DIFFERENT PRESSURE RANGES FOR
PAM 10VC (WITHOUT DISPLAY) AND PAM 10VC D (WITH DISPLAY):

0 to 50 Pa / -50 to +50 Pa
0 to 100 Pa / -100 to +100 Pa


8 DIFFERENT PRESSURE RANGES FOR
PAM 11VC (WITHOUT DISPLAY) AND PAM 11VC D (WITH DISPLAY):

0 to 100 Pa / -100 to +100 Pa
0 to 300 Pa / -300 to +300 Pa
0 to 500 Pa / -500 to +500 Pa
0 to 1000 Pa / -1000 to +1000 Pa


8 DIFFERENT PRESSURE RANGES FOR
PAM 15VC (WITHOUT DISPLAY) AND PAM 15VC D (WITH DISPLAY):

Note: This is a custom model which is normally made to order. Please enquire about availability.

0 to 1000 Pa / -1000 to +1000 Pa
0 to 2000 Pa / -2000 to +2000 Pa
0 to 3000 Pa / -3000 to +3000 Pa
0 to 5000 Pa / -5000 to +5000 Pa


Accuracy

PAM 10VC and PAM 10VC D (100 Pa) +/-3 Pa at 25 °C
PAM 11VC and PAM 11VC D (1000 Pa)+/-10 Pa at 25 °C
PAM 15VC and PAM 15VC D (5000 Pa) +/-35 Pa at 25 °C

Description Air Pressure Transmitter PAM 1-series

The air pressure transmitter PAM 1-series is used for measuring differential pressure, volume flow in air, above-atmospheric or below-atmospheric.

Applications for air pressure transmitter PAM 1-series are in a clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for monitoring filters, for level measurement or for triggering frequency converters.

Media measured with air pressure transmitter PAM 1-series are air (non-precipitating), or other gaseous non-aggressive, non-combustible media.

PAM 1-series air pressure transmitter is equipped with 4 to 8 pcs DIP switchable measuring pressure ranges and 2 pcs DIP switchable output signals 0-10 Vdc or 4-20 mA.

The air pressure transmitter PAM 1-series can be supplied with or without LCD display.

The piezo-resistive measuring element for air pressure transmitter PAM 1-series is temperature- compensated and guarantees a high degree of reliability and accuracy.

The PAM 1-series air pressure transmitter has a pushbutton for manual zero point calibration and an adjustable offset.

The air pressure transmitter PAM 1-series is supplied including duct fixing kit (2 plastic tubes with integrated mounting plate, 2 meters PVC hose and 4 screws).

The PAM 1-series air pressure transmitter has high ingress protection IP67


4 DIFFERENT PRESSURE RANGES FOR
PAM 10VC (WITHOUT DISPLAY) AND PAM 10VC D (WITH DISPLAY):

0 to 50 Pa / -50 to +50 Pa
0 to 100 Pa / -100 to +100 Pa


8 DIFFERENT PRESSURE RANGES FOR
PAM 11VC (WITHOUT DISPLAY) AND PAM 11VC D (WITH DISPLAY):

0 to 100 Pa / -100 to +100 Pa
0 to 300 Pa / -300 to +300 Pa
0 to 500 Pa / -500 to +500 Pa
0 to 1000 Pa / -1000 to +1000 Pa


8 DIFFERENT PRESSURE RANGES FOR
PAM 15VC (WITHOUT DISPLAY) AND PAM 15VC D (WITH DISPLAY):

Note: This is a custom model which is normally made to order. Please enquire about availability.

0 to 1000 Pa / -1000 to +1000 Pa
0 to 2000 Pa / -2000 to +2000 Pa
0 to 3000 Pa / -3000 to +3000 Pa
0 to 5000 Pa / -5000 to +5000 Pa


Accuracy

PAM 10VC and PAM 10VC D (100 Pa) +/-3 Pa at 25 °C
PAM 11VC and PAM 11VC D (1000 Pa)+/-10 Pa at 25 °C
PAM 15VC and PAM 15VC D (5000 Pa) +/-35 Pa at 25 °C

Picture of VCP Differential Pressure Transmitter, IP67 Rating - PAM 10VC
$203.00 ex GST
i h
Picture of VCP Differential Pressure Transmitter, IP67 Rating, with display - PAM 10VC D
$254.00 ex GST
i h
Picture of VCP Differential Pressure Transmitter, IP67 Rating - PAM 11VC
$203.00 ex GST
i h
Picture of VCP Differential Pressure Transmitter, IP67 Rating, with display - PAM 11VC D
$254.00 ex GST
i h