Compressed Air & Leakage Monitoring

Finding, quantifying and eliminating compressed air leaks


Compressed air is one of the most expensive forms of energy. It is produced by compressing ambient air with a compressor. Impurities in the compressed air can cause higher waste if they come into contact with the end product.

The quality of the compressed air produced can cause production issues and as a result, have an impact on operating costs. This is why compressed air is required to be treated after it is generated to remove water, oil, dust particles and other impurities to improve the quality and thus, avoid these issues.

The compressed air system must be designed to produce the correct quantity and quality of air as well as achieving maximum efficiency to avoid additional costs. The greatest savings potential is achieved by locating and repairing leaks in the system to ensure this efficiency is met.

Identifying leaks in compressed air systems are not as easily as detectable water systems, for example. It is recommended that you perform a leakage location on a regular basis in order to find and fix leaks in order to save you money. 

A variety of instruments are used for leak detection. The most common instruments used for this task include portable acoustic devices that can detect air leaks through sound, and sensitive inline flow meters which will give totalisation when there should be none!

View the range >>


Which compressed air flow meter should be used at which point?



Learn more in CS Instruments Basis for measuring leakage in compressed air systems research article.

Download PDF Here >>




Leak Detection Applications


Reduction of energy costs and CO2 emissions through the combination of flow measurement and leakage detection in compressed air


Example 1: A pharmaceutical company

High compressed air leakage rates and incorrectly sized components (compressors and compressed air receivers) reduce the efficiency of your compressed air system and generate unnecessary CO2 emissions and reduce competitiveness. How much compressed air a production requires over a week and how components need to be sized so that they run as efficiently as possible and are utilized to their capacity, can be measured with a compressed air flow meter. In the graph shown, you can see the volume flow profile measured behind the compressed air tank of a pharmaceutical company for about 10 days. The green curve corresponds to the actual measured volume flow profile (moving average) and the red curve corresponds to the volume flow profile after the "simulated" leakage elimination. As you can see, the entire curve shifts downward.


During the times marked in red, production was at standstill and did not produce any goods - i.e., at that time compressed air escaped solely via leakages and open nozzles.

This value should always be as low as possible and should decrease after leakages have been eliminated.

In the graph shown, the following improvements are based on the following assumptions:

  • Specific power: 20,388 kW / 100 cfm
  • Electricity price: 10 €Cent / kWh
  • Running time: 8000 h/ year
  • CO2 emissions electricity mix domestic consumption: 0,837 pound / kWh


Example 2: A bakery business

The following graph shows the volume flow profile of a bakery:

  • The bakery consists of 2 production halls.
  • Hall 1 (older equipment) is shut down temporarily
  • In hall 2 production starts at 10:00 am

A VA 500 (thermal flow sensor) was installed behind the compressed air tank to measure the consumption of the two halls.

In the original volume flow profile (light green) you can see the compressor switching on and off. Therefore, the moving average was calculated additionally (dark green).

The following findings can be derived from this:

  • Although there was no production before 10:00 am, the compressor delivers a lot of compressed air.
  • The "production peaks" are very small compared to the base load

This indicates a very high leakage rate. To confirm the assumption, the ball valves to the machines were closed in the shutdown area in hall 1, so that their leakages are no longer supplied with compressed air.

The volume flow profile shows that the base load can be reduced enormously from closed ball valve to closed ball valve, thus demonstrating the influence of leakage elimination on the compressed air profile.

  • Volume flow at the beginning: 88,28 cfm
  • Volume flow after closing the ball valves: approx. 23,54 cfm

When the equipment in Hall 1 is operated again, the ball valves must be opened and thus compressed air escapes again via the leakages on and in the machines.


Recommended procedure for reduction of compressed air leakage rate

The process described here should be carried out cyclically in the company in order to keep the leakage rate as low as possible in the long term. The aim of the measures should be to achieve a permanent leakage rate of 5-10%, as experience has shown that a one-off search and rectification does not permanently reduce the leakage rate and new leaks will naturally occur again afterwards.

A



Discover the range of instruments to help detect these leaks below or contact us for assistance today!

Display per page

CS Instruments VA 550 - Thermal mass flow sensor for flow measurement

The immersion flow meter VA 550 is the ideal flow sensor for installation into existing compressed air resp. gas lines from 3/4“ up to DN 2000
call for pricing

CS Instruments FA 500 - Dew point sensor (-80°C to 20°C)

FA 500 is the ideal dew point sensor with integrated display and alarm relay for refrigeration, membrane and desiccant driers.
call for pricing

CS Instruments FA 550 - Dew Point Sensor

Robust dew point sensor for compressed air and gases in a die-cast aluminium housing
call for pricing

CS Instruments LD 500/510 - Ultrasound Camera for Air & Gas Leak detection

Shows exactly where compressed air leaks are on the screen and makes finding compressed air leaks much easier – even in harsh environments!
call for pricing

CS Instruments LD 500/510 - Air & Gas Leak detector with camera

Leak detector with a camera – indicates leakage rate in [l/min or cfm] and costs in country currency [ e.g. $ / year]
call for pricing

CS Instruments VA 500 - Flow meter for compressed air & gases

Thermal massflow sensor for compressed air and gases. With our VA500 it is possible to monitor your consumption and analyze your leakage flows with just one measuring device.
call for pricing

CS Instruments VA 520 - Thermal mass flow meter for flow measurement

Flow meters for compressed air as well as various technical gases.
call for pricing

CS Instruments VA 521 - Compact Inline flow meter for compressed air & other gas types

Reduce your energy costs and increase your sustainability with the VA 521. Monitor the consumption of each machine and analyze your leakage flows with just one measuring device.
call for pricing

CS Instruments VA 525 - Compact in-line flow sensor

Flow sensor with integrated flow straightener / no inlet sections necessary. The newly developed VA 525 combines modern digital interfaces for connection to an energy monitoring system with a small, compact design.
call for pricing

CS Instruments VD 500 - Flow sensor for wet compressed air

Reduce your energy costs and increase your efficiency with the VD 500. Suitable directly for measurement after the compressor. Monitor the delivery rate of your compressor and create a FAD analysis.
call for pricing