Description
Push-in measuring probes replaceable within seconds are the main benefit of this series.
Calibration data directly stored in the probe permit a possibly necessary replacement of probes without any loss of precision. Moreover, precision calibration methods and the latest micro-processor technology guarantee a reliable measurement and high measuring accuracy throughout the entire range of application. The exceptional longevity is based on many years of experience gained from the capacitive humidity probes used.
For applications in somewhat higher ambient temperatures, in confined spaces or simply to extend the probe, optionally available adapter cables in lengths of 2 m, 5 m or 10 m can be installed between the measuring probe and the measured value transducer.
The usual voltage outputs of 0 ... 1V, 0 ... 5V, 0 ... 10V or 4 ... 20mA (2 conductor) current outputs area available as output signals, knowing that temperature scaling can be factory-adapted to the desired ranges.
An optionally integrating LC display permits the alternating display of the current humidity and temperature values directly at the device.
On-site calibration of humidity and temperature
Loop calibration of humidity and temperature output values recommended by FDA (Food and Drug Administration) for the pharmaceutical and bio-technological industry is very easily accomplished by means of rF and T measuring probes, which are also separately available. Required adjustment of both analog outputs can be easily achieved through the function keys provided inside the device.
Reference probes
The reference probes available as accessory items offer the possibility of checking the measuring loop for function and precision. Both reference probes can be fitted in lieu of the replaceable
measuring probes. They emit fixed humidity and temperature values. The reference probes are supplied together with a test report, and simulate a high humidity and a low temperature value and vice versa (probe 1: 90% rF/5°C and probe 2: 10% rF/45°C). This permits checking both analog outputs at the upper or at the lower scale end.
Features
For measuring relative air humidity and temperature
- Measurement throughout the entire humidity range from 0 ... 100% rF
- Intelligent easily replaced exchange probes
- For application temperatures between -40 ... +80°C
- Optional with separate measuring probes for humidity and temperature
- 2 m, 5 m or 10 m long adapter cable for probe extension
- Sturdy metal case, suitable for wet rooms
- Integrated LC display (optional)
- With standardized current or voltage outputs
Applications
For versatile applications in the sectors of:
- Climate measuring technology
- Pharmaceutical industry
- Greenhouses
- Clean rooms
- Storages
- Cold stores