The GL260 Data Logger offers a 10-channel capacity with isolated, multi-function inputs, allowing measurement of voltage and temperature. It records data at intervals from 10 milliseconds to 1 hour, providing flexibility for various monitoring needs. An optional Wireless LAN unit enables wireless measurement and remote monitoring. Additionally, the "G-REMOTE" service enhances measurement efficiency through remote control capabilities*
*G-REMOTE Coming Soon
Features
- Includes three new functions: Alarm history, Improved Inter-CH calculation, and Memory loop function.
- Enhanced usability for a better user experience.
- Supports isolated and multi-function input across all channels.
- Capable of capturing data at a sampling interval of up to 10ms by limiting the number of channels.
- Optional WLAN unit available for wireless measurement and remote monitoring with a PC
All Channel Isolated / Universal Input, Standalone Multi-Channel
Voltage, temperature, and humidity can be selected for each input channel.
Use EU scaling for other measurement parameters.
Measure voltage
Supports wide operating range (from 20 mV to 100 V)
Measure temperature
Thermocouple : K, J, E, T, R, S, B, N, C (WRe5-26)
Measure current (4 -20 mA)
Shunt resistor (250Ω) is available as an option. Equipped with a dedicated 1-5V range for the measurement range
- Shunt resistance 250Ω (B-551)
Measure humidity
A humidity sensor is available as an option.
Power for the sensor is also supplied from the main unit. Equipped with a dedicated humidity range
Digital I/O port available
Digital I / O can be used by connecting an optional I / O cable.
- Input/Output cable (B-513)
Logic/Pulse inputs (4 channels)
Logic: No-voltage contact (A contact, B contact, NO, NC) ,Open collector, Voltage input (H.L decision)
Pulse: 3 types of selections (Rotation / Quantity count / Instantaneous) per channel
<Alarm output: 4ch>
Alarm conditions can be set for each input channel.
Signal output from outputs 1 to 4 is possible in the event of an alarm.
Maximum Sampling Interval of Up to 10ms
Up to 10ms sampling speed is achievable when limiting the number of channels in use.
(insert table)
Built-in 8GB Flash Memory with SD Card Support
The Recorded data
(insert table)
- Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
- Sampling interval is limited by the number of channels in use.(10ms:1ch, 50ms:5ch, 100ms:10ch)
Ring capture function
The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)
Relay capture function
Data is continuously saved to multiple files up to 2GB without losing any data until capturing is stopped when the memory is configured in the relay mode.
Memory loop function
In addition to the existing relay capture function, the oldest file is automatically deleted before memory capacity runs out.
Hot-swapping the SD memory card
SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
Back up recording data
The data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.
Backup interval: 1, 2, 6, 12, 24 hour(s)
Backup file destination: SD memory card or FTP server
Data file format: GBD (binary) or CSV (text)
- The CSV format is available with firmware version 1.43 or rater.
• Available sampling speed is the 100 ms or slower when using the CSV format.
• When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
• The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
• When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
Data file verification
It is a function to check the integrity of the data file when replaying the data file. It compares check-sum generated from the data file and recorded check-sum. When two check-sums do not match, the data file may be corrupted or has been changed by someone. The check-sum code is recorded into the file when data file is created by the GL unit.
- Check-sum code is added to normal data recording file and also file created for backup, ring or relay recording. Adding check-sum is available for data files created in GBD format. When the recorded data file is converted and saved using GL100_240_840-APS or GL-Connection software, the check-sum code will not match.
- This function is available with firmware version 1.43 or rater.
Useful functions
- Alarm output function
- Alarm history function
- Improved Inter-CH calculation
- AUTO span
- USB drive mode
- 3 Types of power source
Operability improvements
- Accelerated Web server function
- Simplified waveform setup
- Hide unnecessary menus
- Display HELP QR Code
- Improved visibility (Improved display saturation and MENU tree / New font)