Search
Menu Close

HOBO 2-Sensor Adapter | MX800 Series

Manufacturer:
This adapter lets you monitor multiple parameters by connecting any two MX800 Series sensors—DO, CT, and/or CTD—to a single HOBO MX800 water quality data logger.
Part Number: W-ADAPT-2
Back to Previous Page
$826.00 ex GST
i h

Advanced Multiparameter Monitoring with the MX800 Series Dual Sensor Adapter

This adapter supports the connection of any two compatible sensors to one MX800 data logger - Dissolved Oxygen, Conductivity Sensor, and CTD sensor.

Sensors can be attached directly to the fully submersible MX801 model, or to the end of a W-series cable that's connected to the direct-read MX802 model. Two sensors of the same type can be attached to monitor at multiple depths. When using a DO with CT or CTD combination, salinity-adjusted DO readings are logged directly without a need to perform post-processing.

The 2-sensor adapter comes with a sensor guard that screws onto the adapter to prevent damage to sensors while allowing ample water flow. Users also have an option to purchase an additional anti-biofouling guard (W-GUARD-2), which extends time between sensor cleanings by reducing fouling of the sensor.


Features

  • Can connect sensors directly (MX801), or cables to sensors (MX802)
  • Protective housing screws on and off for easy access to sensors

Technical Information

Length
Full length: 12.3"
Full length with W-GUARD-2 Anti-Fouling Guard: 12.5"
Diameter
2.385"
With W-GUARD-2 Copper Anti-Fouling Guard: 2.5"

Advanced Multiparameter Monitoring with the MX800 Series Dual Sensor Adapter

This adapter supports the connection of any two compatible sensors to one MX800 data logger - Dissolved Oxygen, Conductivity Sensor, and CTD sensor.

Sensors can be attached directly to the fully submersible MX801 model, or to the end of a W-series cable that's connected to the direct-read MX802 model. Two sensors of the same type can be attached to monitor at multiple depths. When using a DO with CT or CTD combination, salinity-adjusted DO readings are logged directly without a need to perform post-processing.

The 2-sensor adapter comes with a sensor guard that screws onto the adapter to prevent damage to sensors while allowing ample water flow. Users also have an option to purchase an additional anti-biofouling guard (W-GUARD-2), which extends time between sensor cleanings by reducing fouling of the sensor.


Features

  • Can connect sensors directly (MX801), or cables to sensors (MX802)