Make Your Energy Audits Easier and More Efficient with our 4-channel Analogue Data Logger

A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. This logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.

The HOBO 4-Channel Analog data logger has 16-bit resolution and can record up to 1.9 million measurements or events. The four external channels accept a variety of sensors, including temperature and split-core AC current sensors as well as 4-20 mA and voltage input cables (sold separately). Using HOBOware®, you can easily configure an alarm to trip when the sensor reading rises above or falls below a measurement that you specify. Or, you can set up burst logging in which the logger records data at a different interval during certain conditions. The logger can also calculate minimum, maximum, average, and standard deviation statistics. This easy-to-use data logger has a built-in LCD screen to check current readings and to monitor logging status, battery use, and memory consumption in between readouts.



Features

  • Twice the accuracy of previous models with 16-bit resolution
  • Flexible support for a wide range of external sensors
  • LCD confirms logger operation and displays near real-time measurement data
  • Provides minimum, maximum, average, and standard deviation logging options
  • On-screen alarms notify you when a sensor reading exceeds set thresholds
  • Stores 1.9 million measurements for longer deployments between offloads
  • Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis


Important Information

External sensors sold separately. Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w/HOBOware Pro CD or USB software purchase). See Related Products below.

Introducing New HOBO UX120 4 Channel Analog Logger

This live,1-hour webinar introduces our new 4-channel HOBO UX120-006M Analog Logger, Onset's highest-accuracy LCD display data logger.

This free webinar is ideal for energy engineers, facility managers, and others interested in an easy and affordable logger for building performance applications, from energy audits and building commissioning studies to building equipment scheduling.

HOBOware Software

HOBOware software is used for launching, reading out, and plotting data from HOBO® data loggers. With HOBOware, you can also check logger status, filter and export data, save changes to graphs in project files, and scale data with the Linear Scaling and Pulse Scaling data assistants. There are two versions of HOBOware: HOBOware and HOBOware Pro.


HOBOware Standard features

  • Simple menus for fast, easy logger setup and readout
  • Point & click for fast setup and readout
  • Scaling to real-world engineering units
  • Presentation-quality graphs
  • Easy export of data files to text or Excel format

FREE DOWNLOAD


Learn more about HOBOware and HOBOware-Pro Features >>


IMPORTANT: This HOBO data logger requires HOBOware software and a communications cable (see related products below)


Technical Information

Logger with
Cable Type
CABLE4-20mA  CABLE-2.5-
STEREO
CABLEADAP5 CABLEADAP10 CABLEADAP24
Measurement
Range
0 to 20.1 mA 0 to 2.5 V 0 to 5.0 V 0 to 10 V 0 to 24 V
Accuracy  ±0.001 mA
±0.2% of
reading
±0.1 mV
±0.1% of
reading
±0.2 mV
±0.3% of
reading
±0.4 mV
±0.3% of
reading
±1.0 mV
±0.3% of
reading
Resolution  0.3 µA 40 µV 80 µV 160 µV 384 µV

Logger

Operating Range Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
Logging Rate 1 second to 18 hours, 12 minutes, 15 seconds
Logging Modes  Fixed interval (normal), burst, or statistics
Memory Modes Wrap when full or stop when full 
Start Modes Immediate, push button, date & time, or next interval 
Stop Modes When memory full, push button, or date & time 
Restart Mode Push button
Time Accuracy ±1 minute per month at 25°C (77°F), see Plot A in User Manual
Power Source Two AAA 1.5 V alkaline batteries, user replaceable, and USB cable 
Battery Life  1 year, typical with logging rate of 1 minute and sampling interval of 15
seconds or greater
Memory 4 MB (1.9 million measurements, maximum)
Download Type USB 2.0 interface
Full Memory Download
Time
Approximately 1.5 minutes
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)
Weight 107.5 g (3.79 oz)
Environmental Rating IP50
CE The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).

Note: The HOBO U-Shuttle (U-DT-1) is not compatible with this logger.

Make Your Energy Audits Easier and More Efficient with our 4-channel Analogue Data Logger

A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. This logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.

The HOBO 4-Channel Analog data logger has 16-bit resolution and can record up to 1.9 million measurements or events. The four external channels accept a variety of sensors, including temperature and split-core AC current sensors as well as 4-20 mA and voltage input cables (sold separately). Using HOBOware®, you can easily configure an alarm to trip when the sensor reading rises above or falls below a measurement that you specify. Or, you can set up burst logging in which the logger records data at a different interval during certain conditions. The logger can also calculate minimum, maximum, average, and standard deviation statistics. This easy-to-use data logger has a built-in LCD screen to check current readings and to monitor logging status, battery use, and memory consumption in between readouts.



Features

  • Twice the accuracy of previous models with 16-bit resolution
  • Flexible support for a wide range of external sensors
  • LCD confirms logger operation and displays near real-time measurement data
  • Provides minimum, maximum, average, and standard deviation logging options
  • On-screen alarms notify you when a sensor reading exceeds set thresholds
  • Stores 1.9 million measurements for longer deployments between offloads
  • Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis


Important Information

External sensors sold separately. Requires HOBOware software and a USB cable. (Note: A USB-A to USB-B mini cable is included w/HOBOware Pro CD or USB software purchase). See Related Products below.

Customers who bought this item also bought

HOBO - 4-20 mA Input Cable

For connecting a sensor with a 4-20mA output to a HOBO U12, UX120, or ZW series external-channel data logger.
$84.00 (ex gst)

HOBO Split-core AC Current Sensors

A split-core sensor to record AC amperage; for use with HOBO U12, UX120-006M, MX1100, and ZW series data loggers with external input channels.
from $378.00 (ex gst)

HOBO Temperature Sensors for UX120 & U12 Series HOBO Data Loggers

A temperature sensor for use with HOBO UX Series external-channel data loggers, this model measures temperature in air, water, or soil.
from $95.00 (ex gst)