Also see install manual PDF for full specifications
Specifications.
Input 1 x wet bulb, 1 x dry bulb.
Dual 3-wire RTD Pt100 DIN (JIS option).
Power supply HV: 85~265Vac / 95~370Vdc.
LV: 15~48Vac / 10~72Vdc.
Analogue Output Temperature and humidity output. Dual 16-bit 4~20mA (fully scalable). Window
programmable over any range within the full-scale range of the controller.
Sampling rate 2.5Hz.
Resolution 0.025% full scale 16-bit.
Accuracy 0.05% of reading.
Temperature drift Typically 50ppm/°C.
Temperature units °C or °F.
Easy Setup Intuitive text prompts for easy setup.
Calibration Precalibrated for Pt100 RTD. Simple recalibration (if required) using high and low
display values.
Security Calibration and setpoint functions have independent security code access.
Setpoint functions are independently configurable, and accessible through the F2 key.
OPTIONAL
Relay Output 4x 5A Form A relays.
Serial port
Isolated RS232 or RS485.
Modes: ASCII, Modbus RTU