The InTemp CX602 & CX603 Dry Ice loggers are designed for cold shipment monitoring and have a built-in external probe that can measure temperatures as low as -95°C with a protective sheath to prevent accidental cutting of the cable, and a clip for secure mounting.
Part Number: CX60X
Manufacturer:
0Types Available
Back to Previous Page

The InTemp CX602 and CX603 Dry Ice data loggers are Bluetooth Low Energy (BLE)-enabled data loggers that records temperature. The built-in 1.5m probe measures temperatures as low as -95°C (-139°F) and includes a protective sheath to prevent accidental cutting of the cable, and a clip for secure mounting.

Using the InTempApp on your mobile device, you can easily configure the CX600 loggers with one of the multiple preset configurations, or set up a custom configuration. The logger has a built-in alarm to alert you to excursions and logger reports can be quickly downloaded to your phone or tablet, where you can analyze and export data as needed.


Highlighted Features

  • Anti-cut sheath
  • Integrates with mobile and cloud platforms for a 21CFR Part 11 compliant solution
  • Compact and lightweight – ideal for shipping pharmaceuticals
  • No need to open containers to access data
  • Ensures secure data via encrypted technology
  • IATA Battery compliant

 


Configure & Readout InTemp Loggers with the InTemp App

The free InTemp app makes it a snap to configure and read out InTemp loggers. View data, check logger status, set alarms, and create and share secure PDF reports to streamline reporting and compliance.

With the app, you can choose from preset configurations (for refrigerator, storage, freezer and more) or create your own configuration for other monitoring applications. To keep things secure, you can set an encrypted passkey that other mobile devices will require for connection to the logger.

Important: The InTemp CX Series of data loggers require the InTemp App and a compatible mobile device.


Need Cloud Base Reporting?

Build a system with the addition of the InTemp CX5000 Gateway, where users can get text or email notifications of temperature excursions, as well as automatic data downloads from loggers within range of the CX Gateway device.


 


Calibration

InTemp data loggers have an accuracy of +/­ 0.5 ºC and come with a NIST certificate of calibration. Advanced certificates of calibration are also available for applications requiring an ISO 17025 compliant certificate.

Certificate is valid for 12 months from the date of manufacture.


Important Information - Certificate of Validation. 

The validation certificate supplied with this instrument is from date of manufacture, therefore due to receipt of goods time and shelf time may be partly or fully expired.

It is deemed by OneTemp Pty Ltd that this instrument is not supplied with current certificates of validation. If you need current certificates, please discuss the options we have available before ordering. 


InTemp App for InTemp CX Data loggers

The free InTemp app makes it a snap to configure and read out InTemp loggers, and automatically upload reports to the InTempConnect cloud service. View data, check logger status, set alarms, and create and share secure PDF reports to streamline reporting and compliance.

With the app, you can choose from preset configurations (for refrigerator, storage, freezer and more) or create your own configuration for other monitoring applications. To keep things secure, you can set an encrypted passkey that other mobile devices will require for connection to the logger.


Features:

✔ Connected Screen
✔ Easy Configuration
✔ Alarms
✔ Quick Checks


Learn More >>

Technical Information

CX602 - Single Use

CX603 - Multi Use

Temperature Probe

Sensor Range -95° to 50°C (-139° to 122°F) -95° to 50°C (-139° to 122°F)
Accuracy ±1.5°C from -95° to -40°C (±2.7°F from -139° to -40°F)
±1.0°C from -40° to -10°C (±1.8°F from -40° to 14°F)
±0.5°C from -10° to 50°C (±0.9°F from -14° to 122°F)
±1.5°C from -95° to -40°C (±2.7°F from -139° to -40°F)
±1.0°C from -40° to -10°C (±1.8°F from -40° to 14°F)
±0.5°C from -10° to 50°C (±0.9°F from -14° to 122°F)
Resolution 0.013°C at 25°C (0.023°F at 77°F) 0.013°C at 25°C (0.023°F at 77°F)
NIST Calibration Three-point NIST calibration, probe only Three-point NIST calibration, probe only
Cable Length 1.5 m (4.92 ft) 1.5 m (4.92 ft)
Probe Dimensions Food-grade stainless steel probe with blunt tip, 31.75 mm (1.25 inches) long, 4.78 mm (0.188 inches) diameter Food-grade stainless steel probe with blunt tip, 31.75 mm (1.25 inches) long, 4.78 mm (0.188 inches) diameter

Logger

Logger Operating Range -30° to 50°C (-22° to 122°F) -30° to 50°C (-22° to 122°F)
Radio Power 1 mW (0 dBm) 1 mW (0 dBm)
Transmission Range Approximately 30.5 m (100 ft) line-of-sight Approximately 30.5 m (100 ft) line-of-sight
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart) Bluetooth Low Energy (Bluetooth Smart)
Type Single use Multi Use
Duration 90 days 365 Days
Shelf Life Up to 1 year Up to 1 year
Logging Rate 1 second to 18 hours 1 second to 18 hours
Battery CR2450 3V lithium, not replaceable. Battery for CX602 and CX702 models lasts for duration specified when logger is used within the 1-year shelf life. Battery life for the CX603 and CX703 models is 1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive downloads, and paging may impact battery life. CR2450 3V lithium, not replaceable. Battery for CX602 and CX702 models lasts for duration specified when logger is used within the 1-year shelf life. Battery life for the CX603 and CX703 models is 1 year, typical with logging interval of 1 minute. Faster logging intervals, remaining connected with the InTemp app, excessive downloads, and paging may impact battery life.
Memory 16,000 measurements  16,000 measurements 
Full Memory Download
Time
Approximately 30 seconds; may take longer the farther the device is
from the logger
Approximately 30 seconds; may take longer the farther the device is
from the logger
Dimensions 6.9 x 4.5 x 1.1 cm (2.71 x 1.76 x 0.42 inches) 6.9 x 4.5 x 1.1 cm (2.71 x 1.76 x 0.42 inches)
Weight 25.5 g (0.90 oz) 25.5 g (0.90 oz)
Environmental Rating IP65 IP65
CE The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).
The CE Marking identifies this product as complying with all relevant
directives in the European Union (EU).

InTempVerify is a free mobile app that allows activation of data downloads by delivery drivers to provide you with real time enroute temperature status.

Combining the automation benefits of a wireless (Bluetooth/cloud) solution with the data accessibility of a USB logger, InTempVerify is a free mobile app that allows activation of data downloads by anyone, anywhere, anytime!

Simply program your loggers to be recognized by InTempVerify and, with just the push of a button, anyone in the world with the app can download data and send it straight to your InTempConnect account. Plus, users can view alarms and real-time data while in range of the loggers and make critical decisions on the spot. No need to plug the logger into a computer or cradle, no need to manually send data and reports, and no need to worry about getting crucial data to the right people, on time!


Features:

✔ One-time Sign-in
✔ Highly Secure
✔ One-tap Downloads
✔ Auto Data Delivery
✔ Data in Real Time
✔ Get Notified


Learn More >>


InTemp Data Loggers: Getting Started, Out of the Box

A video explaining how to set up, configure and start logging with your new InTemp data logger.


ONSET InTemp CX400 Series

The InTemp CX400 Series is a family of high-performance data loggers for monitoring temperatures in refrigerators, freezers, and other temperature-controlled environments. Designed for pharmaceutical GDP compliance, with specific models for the CDC Vaccines for Children Program, InTemp loggers dramatically simplify your process by streamlining daily operations including manual temperature checks and reducing your paper trail burden. Leveraging Bluetooth communication from today’s mobile devices and the convenience of an app, logger setup and readout times are fast and easy.


How To Launch InTemp CX Data Loggers with the Mobile App

This video will show users who have previously set up their InTempConnect account, how to launch any InTemp CX data logger with the InTemp mobile app.



InTemp - Basic Concepts

Learn the basic concepts of how the InTemp and InTempConnect products work with the InTemp CX series data loggers.


Learn a Whole New Way to Monitor Vaccine Storage Temperature - Introduction Webinar 39min

With new InTemp CX400 data loggers, monitoring temperature-sensitive vaccines has never been so effortless.


Learn a Whole New Way to Optimize Temperature Monitoring for the Pharmaceutical Supply Chain - 60min

Discover InTemp from Onset - an entirely new, fully-integrated, end-to-end temperature monitoring technology for Good Distribution Practices in the pharmaceutical supply chain.


Reduce Logistics Costs for Temperature-Sensitive Products with New Technology

Learn about a fully-integrated temperature monitoring solution that provides automated data download, alerting, and reporting, enabling greater access to data while reducing the time and money spent on data retrieval and excursion investigation.


Onset InTemp CX Gateway

Watch the video to learn how InTemp data loggers connect seamlessly to the CX Gateway device and InTempConnect cloud-based data warehousing service, providing real-time notification of temperature excursions via email or text. Data can be automatically downloaded from one or more InTemp loggers within range of the CX Gateway, reducing the burden of manually downloading data from the loggers.


Cost Effective IoT Solutions for Cold Chain Visibility

Cost-effective IoT InTemp monitoring solutions provide complete visibility across all cold chain shipping environments. Learn more about this streamlined process for data logger deployment and the management and collection of data. This webinar presents: -An overview of InTempConnect, Onset’s cloud-based data warehousing service, with a new shipment feature -Solutions that can help you conduct shipping studies while reducing supply chain costs


Why isn't my logger appearing in the list on the Loggers screen in the InTemp app?

  • The logger is not within range of the phone or tablet or something is obstructing the communication. Move closer to the logger. The range for successful wireless communication is approximately 30.5 m (100 ft) with full line-of-sight.
  • Bluetooth may not be enabled for your device. Make sure Bluetooth is enabled in your phone or tablet’s settings.
  • Press the button on a CX500, CX600, and CX700 logger to wake it up.
  • The CX400 or CX450 logger may need new batteries. Symbols will appear on the logger LCD if the batteries have enough voltage remaining and are installed properly.


My logger is within range of the phone or tablet and Bluetooth is enabled. Why isn’t it appearing in the InTempVerify app?

To be visible in the InTempVerify app, the logger must be configured with a logger profile in which the “InTempVerify (ITV) enabled” option was selected. If that option was not enabled, then the logger will not appear in the InTempVerify app even if it is within the range of the phone or tablet. See Managing Profiles for details.


I see my logger in the InTemp or InTempVerify app, but I can't connect to it. What can I do?

  • Close the app and then reopen it.
  • Power cycle the mobile device (turn the power off, wait a few seconds, and then turn it back on) and try connecting again.
  • Change the orientation of your phone or tablet to ensure the antenna in your device is pointed toward the logger. Obstacles between the antenna in the device and the logger may result in intermittent connections.
  • If you are an InTempConnect user and are using the InTemp app, make sure you have the required privileges. Contact your administrator for help.


I was setting up my logger with the InTemp app and then I lost the connection. Will my logger still start?

If you did not tap Start before the connection was lost, then the configuration settings will not be loaded to the logger and it will not start logging. Connect to the logger again, finish choosing your configuration settings, and then tap Start.


How do I lock my logger so that no one else can configure it?

If you use the InTemp app only (not logged in as an InTempConnect user), you can set a passkey for the logger. Connect to the logger and tap Set Logger Passkey. Enter a password up to 10 characters. The passkey will then be required any time another mobile device attempts to connect to the logger with the InTemp app. The device that configured the logger, however, will automatically retain the passkey so you do not have to type in a passkey each time that device connects to the logger.

If you are an InTempConnect user, a passkey is automatically generated for each individual user associated with the same administrator account. Administrators or those who the required privileges can view the passkey associated with a logger on the detailed logger configuration page in InTempConnect if it is needed (see Viewing Details about Logger Configurations).


How do I reset the passkey on a logger?

If you are using the InTemp app only (not logged in as an InTempConnect user), tap Reset Passkey to Factory Default on the Set Logger Passkey screen or simultaneously press both the top and bottom buttons on the logger for 5 seconds (CX400 and CX450 loggers only).

If you are logged in to the InTemp app as an InTempConnect user and you see an invalid passkey message, it is because your user account is not associated with the administrator account used to configure the logger. Contact your InTempConnect administrator for help to retrieve the key. If you have Reset Logger Passkey privileges, then a Reset Logger Passkey option is available when connected to the logger.


How do I offload my logger with the InTemp app?

Connect to the logger and tap Download. Once the download is complete, a report is generated for sharing. InTempConnect users must have the required privileges.


It is taking more than a minute to download my logger with the InTemp or InTempVerify app. Is this normal?

A logger with a full memory should take a minute or less to download. If the download is taking longer than a minute, move the mobile device closer to the logger, within a few feet if possible. The further away the mobile device is from the logger, the longer the download can take.


I changed the units in the InTemp app settings. Why is my CX400 or CX450 logger still displaying the old units?

The units displayed on the CX400 or CX450 logger LCD can only be changed if the logger is reconfigured. To change the units on the logger LCD, select the desired units in Settings in the InTemp app, connect to the logger, tap Configure, choose a profile, and tap Start. The new units will be displayed on the LCD when logging restarts.


I switched to another app and when I returned to InTemp, the Loggers screen was blank. What should I do?

Switch to another screen in InTemp and then switch back. The screen should then appear again as normal.


I am logged into the InTemp app as an InTempConnect user and I'm seeing an invalid passkey message when I try to connect to the logger. What do I do?

Only active users associated with the same InTempConnect administrator account used to configure the logger can connect to it. Contact your InTempConnect administrator to retrieve the key to enter when prompted.


Can I log in as an InTempConnect user and a local user with the same logger on the InTemp app?

Only until the logger is configured. If you are logged into the app as an InTempConnect user and configure the logger, then you will only be able to connect to that logger in the future as an InTempConnect user.


When I log into the InTemp app and tap Devices, I don't see any gateways. Why?

You need to have Gateway Administrator rights to see gateways. Contact your InTempConnect administrator to add the privileges to your user role.


I can see the gateway in the InTemp app, but my mobile device won’t connect to it. What can I do?

  • Make sure the gateway is within range of your phone or tablet. Move closer to the gateway, within sight if possible. Check the gateway signal strength icon in the app to make sure there is a strong signal between the phone and the gateway. The more blue bars, the stronger the signal.
  • Change the orientation of your phone or tablet to ensure the antenna in your device is pointed toward the gateway. Obstacles between the antenna in the device and the gateway may result in intermittent connections.


How can I tell if the gateway is finding all my loggers?

Connect to the gateway. The InTemp app will list how many loggers are in range. Reposition the loggers closer to the gateway if not all are found as expected.


How can I get a NIST certificate for my logger?

To download a NIST certificate (if available):

  • Click Data and then Logger Configurations.
  • Scroll through the table or enter search criteria to find a specific configuration.
  • Click the link in the Logger Label column to view the configuration details page.
  • Under Configuration Info, scroll to NIST Certificate and click Download.


What are the min/max values on my logger LCD and how do I clear them?

On CX400 loggers configured with the daily or twice-daily logger check feature enabled, these values represent the minimum and maximum sensor readings with the current 24-hour period and will reset every 24 hours automatically.

On CX450 loggers and on CX400 loggers configured without the logger check feature enabled, these values represent the minimum and maximum sensor readings over the entire logging period for the current configuration. The values will reset when the logger is stopped or reconfigured.

You can also manually clear the values at any time. Press the Mute/Next button on CX400 loggers for 3 seconds or press both buttons on CX450 loggers for 3 seconds to clear the values. Dashes (--) will then appear on the LCD for the minimum and maximum values until the next logging interval. Note: This clears the data on the screen only. Actual logger and reporting data will not be cleared with this reset.


Discover more resources including White Papers, Technical Notes, Webinars, How to Videos, Documentation Here

Further PDF Guides can be downloaded from here

InTemp data loggers are approved for use on almost every major airline, including;


The InTemp CX602 and CX603 Dry Ice data loggers are Bluetooth Low Energy (BLE)-enabled data loggers that records temperature. The built-in 1.5m probe measures temperatures as low as -95°C (-139°F) and includes a protective sheath to prevent accidental cutting of the cable, and a clip for secure mounting.

Using the InTempApp on your mobile device, you can easily configure the CX600 loggers with one of the multiple preset configurations, or set up a custom configuration. The logger has a built-in alarm to alert you to excursions and logger reports can be quickly downloaded to your phone or tablet, where you can analyze and export data as needed.


Highlighted Features

  • Anti-cut sheath
  • Integrates with mobile and cloud platforms for a 21CFR Part 11 compliant solution
  • Compact and lightweight – ideal for shipping pharmaceuticals
  • No need to open containers to access data
  • Ensures secure data via encrypted technology
  • IATA Battery compliant

 


Configure & Readout InTemp Loggers with the InTemp App

The free InTemp app makes it a snap to configure and read out InTemp loggers. View data, check logger status, set alarms, and create and share secure PDF reports to streamline reporting and compliance.

With the app, you can choose from preset configurations (for refrigerator, storage, freezer and more) or create your own configuration for other monitoring applications. To keep things secure, you can set an encrypted passkey that other mobile devices will require for connection to the logger.

Important: The InTemp CX Series of data loggers require the InTemp App and a compatible mobile device.


Need Cloud Base Reporting?

Build a system with the addition of the InTemp CX5000 Gateway, where users can get text or email notifications of temperature excursions, as well as automatic data downloads from loggers within range of the CX Gateway device.


 


Calibration

InTemp data loggers have an accuracy of +/­ 0.5 ºC and come with a NIST certificate of calibration. Advanced certificates of calibration are also available for applications requiring an ISO 17025 compliant certificate.

Certificate is valid for 12 months from the date of manufacture.


Important Information - Certificate of Validation. 

The validation certificate supplied with this instrument is from date of manufacture, therefore due to receipt of goods time and shelf time may be partly or fully expired.

It is deemed by OneTemp Pty Ltd that this instrument is not supplied with current certificates of validation. If you need current certificates, please discuss the options we have available before ordering. 


Picture of InTemp CX603 - Dry Ice Multiple Use Bluetooth Data Logger
InTemp CX603 - Dry Ice Multiple Use Bluetooth Data Logger
The InTemp CX603 Dry Ice data logger is a Bluetooth Low Energy (BLE)-enabled multiple-use logger that records temperature data for up to 365 days.
Part Number: CX603
$460.00 ex GST
i h
Delivery date: 1-2 weeks
Picture of InTemp CX602 - Dry Ice Single Use Bluetooth Data Logger
InTemp CX602 - Dry Ice Single Use Bluetooth Data Logger
The InTemp CX602 Dry Ice data logger is a Bluetooth Low Energy (BLE)-enabled single-use logger that records temperature data for up to 90 days.
Part Number: CX602
Call for pricing
Delivery date: 1-2 weeks