Manufacturer:
The OPTIFLUX 2000 is a rugged and reliable flow meter designed for water and wastewater applications. It features a fully welded construction, wide diameter range, and easy installation. Compliant with industry standards, it offers extensive diagnostic capabilities and requires no maintenance.
Part Number: OPTIFLUX 2000
Back to Previous Page
Call for pricing

Get Highly Accurate Results You Can Trust with Tamper Proof, Fully Welded Construction

The OPTIFLUX 2000 is designed to meet the demands for all water and waste water applications including groundwater, potable water, waste water, sludge and sewage, industry water and salt water.

The OPTIFLUX 2000 has a field proven and unsurpassed lifetime. This is assured by the fully welded construction, full bore pipe, absence of moving parts and wear resistant liner materials. The sensor has the widest diameter range available in the market: from DN25 up to DN3000.


Features

  • Rugged liners suitable for any water and wastewater application
  • Proven and unsurpassed lifetime, huge installed base
  • Tamper proof, fully welded construction, also available in customer specific constructions
  • Drinking water approvals including KTW, KIWA, ACS, DVGW, NSF, WRAS
  • Suitable for subsoil installation and constant flooding (IP 68)
  • Bi-directional flow metering
  • Compliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, EN 14154)
  • Standard in house wet calibration of sensors up to diameter DN3000
  • Easy installation and commissioning
  • No grounding rings with virtual reference option on IFC 300
  • In-situ verification with OPTICHECK
  • Extensive diagnostic capabilities
  • Maintenance-free


Applications

  • Water abstraction
  • Water purification and desalination
  • Drinking water distribution networks
  • Revenue metering or billing
  • Leakage detection
  • Irrigation
  • Industry water
  • Cooling water
  • Wastewater
  • Sewage and sludge
  • Sea water

Optional Signal Converter for Electromagnetic Flowmeter

The electromagnetic signal converter IFC 050 is a perfect choice for measuring volumetric flow in various kinds of applications in the water industry but also in the food and beverage business.

The signal converter can be combined with the flow sensors OPTIFLUX 1000, 2000, 4000, 5000, 6000 and the WATERFLUX 3000.

The output represents measured values for flow, mass and conductivity.

This low-cost signal converter has some specific features:

  • An active pulse output for a simple system, like driving an electro-mechanical counter
  • RS485 Modbus communication with a data processing system
  • Extra insulation of the electronic device and housing for high performance in areas with extreme humidity and chances for flooding
  • Cost-effective flow measurement for a wide range of process conditions and still a very acceptable degree of accuracy



Technical Information

Signal Converter

Compact version (C) IFC 050 C
Remote version (W) IFC 050 W

Options

Outputs Current output (including HART®), pulse output, frequency output, status output
and/or limit switch
Note: It's not possible to use the pulse/frequency output with the status output at
the same time!
Counter 2 internal counters with a max. of 10 counter places (e.g. for counting volume
and/or mass units)
Verification Integrated verification, diagnostic functions: measuring device, empty pipe
detection, stabilisation
Communication interfaces HART®
Modbus

Technical Information

Measuring Principle Magnetic-inductive
Nominal Widths DN 25 to DN 300
Accuracy 0.5 % of the measured value
Medium Temperature Up to 90 °C
Process Connection PN 40 (DN 25 to DN 80), PN 16 (DN 100 to DN 150), PN 10 (DN 200 to DN 300)
Lining PP, hard rubber
Ambient Temperature Up to 65 °C
Protection Type IP66/IP67, IP68 for remote version
Outputs Analog output (4 to 20 mA) with HART and pulse/frequency/status
Display LCD display, white backlight for displaying up to 3 measured values
Special Features Drinking water approval PP: ACS, DVWG, KTW, WRAS, NSF, KIWA

Get Highly Accurate Results You Can Trust with Tamper Proof, Fully Welded Construction

The OPTIFLUX 2000 is designed to meet the demands for all water and waste water applications including groundwater, potable water, waste water, sludge and sewage, industry water and salt water.

The OPTIFLUX 2000 has a field proven and unsurpassed lifetime. This is assured by the fully welded construction, full bore pipe, absence of moving parts and wear resistant liner materials. The sensor has the widest diameter range available in the market: from DN25 up to DN3000.


Features

  • Rugged liners suitable for any water and wastewater application
  • Proven and unsurpassed lifetime, huge installed base
  • Tamper proof, fully welded construction, also available in customer specific constructions
  • Drinking water approvals including KTW, KIWA, ACS, DVGW, NSF, WRAS
  • Suitable for subsoil installation and constant flooding (IP 68)
  • Bi-directional flow metering
  • Compliant with requirements for custody transfer (MID MI-001, OIML R49, ISO 4064, EN 14154)
  • Standard in house wet calibration of sensors up to diameter DN3000
  • Easy installation and commissioning
  • No grounding rings with virtual reference option on IFC 300
  • In-situ verification with OPTICHECK
  • Extensive diagnostic capabilities
  • Maintenance-free


Applications

  • Water abstraction
  • Water purification and desalination
  • Drinking water distribution networks
  • Revenue metering or billing
  • Leakage detection
  • Irrigation
  • Industry water
  • Cooling water
  • Wastewater
  • Sewage and sludge
  • Sea water