The 0–200 VDC and 0–500 VAC devices are triggered by electricity’s presence or absence in batteries or other sources, such as solar equipment.
Part Number: MNS2-4-W2-VD-xx
Manufacturer:
0Types Available
Back to Previous Page

Always know if it has power

The 0–200 VDC and 0–500 VAC devices are triggered by electricity’s presence or absence in batteries or other sources, such as solar equipment. If a monitored value rises or falls beyond user-set thresholds, an alert is sent via text, email, or call. Know when essential appliances are operative (helpful for remote locations or decentralized operations).

This sensor come standard with two replaceable AA batteries. The typical battery life is approximately 10 years.


Features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Appliance Monitoring
  • Line Power Monitoring
  • Power Coupling Monitoring
  • HVAC Systems Monitoring
  • Power Supply Monitoring
  • Sump Pump Monitoring
  • Backup Generator Monitoring
  • Machine Motor Monitoring


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.


Monnit Gateway Options

An integral component of any IoT network is the gateway. A gateway device allows for data from sensors to be transmitted to the iMonnit software platform.


Monnit Ethernet Wireless Gateway 4

Monnit’s Ethernet Gateways allow your Monnit Wireless Sensors to communicate with the iMonnit™ Online Wireless Sensor Monitoring and Notification System without the need for a PC. Simply provide power and plug the gateway into an open Ethernet network port with an internet connection. It will then automatically connect with our online servers, providing the perfect solution for commercial locations where there is an active internet connection.

Learn more about the Ethernet Wireless Gateway 4>>



Monnit 4G + Ethernet IoT Gateway

The ALTA® by Monnit Wireless IoT Gateway combines a 4G LTE CAT-M1/NB2 cellular engine and Ethernet platform with Monnit’s wireless access point network to aggregate and communicate data from Monnit ALTA Wireless Sensors. The ALTA IoT Gateway allows ALTA Sensors to operate on the world’s leading cellular networks and stay connected to the Internet. The gateway uses AC main power but also has redundant power through a battery backup lasting up to 60 hours.

To meet the global demand for enterprise IoT deployment, the IoT Gateway communicates with the cloud-based iMonnit® monitoring software via cellular transmission, making it ideal for remote locations or where the Internet isn’t available. The RJ-45 Ethernet jack allows local device configuration, diagnostics, and connectivity backup. The IoT Gateway is instrumental in sending sensor notifications via text, email, or call if user-defined conditions are met or exceeded.

Learn more about the 4G + Ethernet Wireless Gateway 4>>


Online Sensor Monitoring Software

iMonnit is a cloud based mobile internet platform and central hub for managing Monnit and ALTA products. All data is secured on dedicated servers operating Microsoft SQL Server. This online user interface is where all your device settings can be arranged, supervised, and modified to reflect your unique environment. OneTemp will look after the activation and setup of your new online iMonnit account free of charge. There is also a free mobile app for you to stay in control at all times. Start with the basic version or upgrade to iMonnit Premiere to enjoy the full features your Monnit experience can offer.


iMonnit Basic Vs Premiere:

  • Basic - Free with no ongoing costs
    Monnit Basic is included for free with all wireless sensors, providing basic features for you to configure and monitor your sensors online. These basic features only support one network and one registered user on an account.
  • Premiere - Minimal Annual Fee
    iMonnit Premiere allows for enhanced functionality of your wireless sensors and includes an advanced software feature set at a low annual cost. All of iMonnit's advanced features are availble for configuration. You can have more sensors on your account, support multiple users, and view floorplans for all your sensors.

Learn more about the iMonnit Premier Online Software>>

 


Technical Information 0-200VDC Voltage Sensor

Supply voltage 2.0-3.8 VDC (3.0-3.8 VDC using power supply) *
Current Consumption 0.2 μA (sleep mode), 0.7 μA (RTC sleep), 570 μA (MCU idle), 2.5
mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA (radio TX
mode)
Operating temperature range (board circuitry and batteries) -18°C to 55°C (0°F to 130°F) using alkaline
-40°C to 85°C (-40°F to 185°F) using lithium **
Optimal battery temperature range (AA) +10°C to +50°C (+50°F to +122°F)
Accuracte range 0-200 VDC ***
Absolute maximum voltage 250 VDC ***
Absolute minimum voltage -250 VDC
Sensor resolution 0.01 VDC
Accuracy +/- (.15 V + 1% of Reading)
Input impedance 665 MOhm
Integrated memory Up to 3200 sensor messages
Wireless range 1,200+ ft non-line-of-sight
Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
Weight 3.7 ounces
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC: 9794A-G2SC1.
868 and 433 MHz product tested and found to comply with: EN
300 220-2 V3.1.1 (2017-02), EN 300 220-2 V3.1.1 (2017-02) and
EN 60950

* Circuit cannot withstand negative voltage. Please take care when installing batteries.
** At temperatures above 100°C, it is possible for the board circuitry to lose programmed memory.
*** The sensor is capable of measuring above 200 volts but may not meet the specified accuracy above this value.



Technical Information 0-500VDC Voltage Detection Sensor

Supply voltage 2.0-3.8 VDC (3.0 - 3.8 VDC using power supply)*
Current consumption 0.2 μA (sleep mode), 0.7 μA (RTC sleep), 570 μA (MCU idle),
2.5 mA (MCU active), 5.5 mA (radio RX mode), 22.6 mA
(radio TX mode)
Operating temperature range (board security and coin cell) -18°C to 55°C (0°F to +130°F) using alkaline
-40°C to 85°C (-40°F to +185°F) using lithium
Optimal battery temperature range (AA) +10°C to +50°C (+50°F to +122°F)
Absolute maximum input voltage 600 VAC rms **
Response time ~1 Second
Minimum detection voltage > 4 VACrms
Interdeterminant detection region 3 - 4 VAC rms ***
Input impedance 2 MOhm
Leaded wire specification 2 Wires, 1 ft (12 in), Black (Line), White (Common), 18 AWG
Datalogging Datalogs 2000 to 4000 readings if gateway connection is lost
(non-volatile flash, persists through the power cycle):
- 10-minute heartbeats = ~ 22 days
- 2-hour heartbeats = ~ 266 days
Wireless range 1,200+ ft non-line-of-sight
Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
Weight 3.7 ounces
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC:
9794A-G2SC1. 868 and 433 MHz product tested and found to
comply with: EN 300 220-2 V3.1.1 (2017-02), EN 300 220-2
V3.1.1 (2017-02) and EN 60950

* Circuit cannot withstand negative voltage. Please take care when installing batteries.
** Connecting to power sources over 600 VAC rms can damage the hardware
*** This sensor may indicate present or absent in this voltage range

Always know if it has power

The 0–200 VDC and 0–500 VAC devices are triggered by electricity’s presence or absence in batteries or other sources, such as solar equipment. If a monitored value rises or falls beyond user-set thresholds, an alert is sent via text, email, or call. Know when essential appliances are operative (helpful for remote locations or decentralized operations).

This sensor come standard with two replaceable AA batteries. The typical battery life is approximately 10 years.


Features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Appliance Monitoring
  • Line Power Monitoring
  • Power Coupling Monitoring
  • HVAC Systems Monitoring
  • Power Supply Monitoring
  • Sump Pump Monitoring
  • Backup Generator Monitoring
  • Machine Motor Monitoring


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.


Picture of Monnit Enterprise Voltage Detection Wireless Sensor (200 VDC)
Monnit Enterprise Voltage Detection Wireless Sensor (200 VDC)
Machine operators and facility managers have a second set of eyes in Monnit’s 200 VDC wireless sensor. This wireless voltage sensor tracks power sources or monitors the on/off status of equipment and machines, as well as battery levels.
Part Number: MNS2-4-W2-VD-200
$458.00 ex GST
i h
Picture of Monnit Enterprise Voltage Detection Wireless Sensor (500 VAC)
Monnit Enterprise Voltage Detection Wireless Sensor (500 VAC)
Monnit’s Voltage Detection Wireless sensor interfaces with a device or system to detect voltages to 500 VAC. If the sensor does (or doesn’t) detect voltage during measurement, you’ll be alerted.
Part Number: MNS2-4-W2-VD-AC
$467.00 ex GST
i h