Intelligent chart recorder DS 500 for compressed air and gases


DS 500 - Intelligent chart recorder

From recording of the measured data, indication on a big colour screen, alerting, storage up to remote read-out via webserver... this is all possible with DS 500. By means of the CS Soft Basic software alarms can be sent via SMS or e-mail. All measured values, measured curves and threshold exceedings are indicated. The curve progressions from the beginning of the measurement can be viewed by an easy slide of the finger. Daily/weekly/monthly reports with costs in € and counter reading in m³ for each consumption sensor are completing the sophisticated system concept. The big difference to odinary paperless chart recorders reveals in the easy initiation and in the evaluation of the measured data. All sensors are identified directly and powered by DS 500. Everything is matched and tuned.


Advantages of DS 500 at a glance

  • Clear layout: 7" colour screen with touch panel
  • Versatile: Up to 12 optional sensors can be connected
  • Suitable for industrial applications: Metal housing IP 65 or panel mounting
  • Data avialable though world wide web: Network-compatible and remote transmission via webserver
  • Intelligent: Daily/weekly/monthly reports
  • Mathematical function for internal calculations
  • Totalizer function for analogue signals
  • Saves time and costs during installation


Mathematical function for internal calculations

e.g. the typical figures of a compressed air plant:

  • costs in € per generated m³ air
  • kwh/m³ generated air
  • consumption of single lines including summation


Totalizer function for analogue signals

e.g. 0/4...20 mA, 0...10 V. In case of third-party sensors which e.g. only give a 4...20 mA signal for the actual flow in m³/h a total counter reading in m³ can be generated by means of the totalizer function.

Technical Information

Dimensions of housing: 280 x 170 x 90 mm, IP 65
Connections: 18 x PG for sensors and supply
Version panel mounting: Cutout panel 250 x 156 mm
Weight: 7.3 kg
Material: Die cast metal, front screen polyester
Sensor inputs: • 4/8/12 sensor inputs for analogueue and digital sensors; freely allocatable. See options
• Digital CS sensors for dew point and consumption with SDI interface FA/VA series,
• digital third-party sensors RS 485 / Modbus RTU, other bus systems realizable on request.
• Analogue CS Sensors for pressure, temperature, clamp-on ammeters pre-configured.
• Analogue third-party sensors 0/4...20 mA, 0...1/10/30 V, pulse, Pt 100 / Pt 1000, KTY
Voltage supply for sensor: 24 VDC, max. 130 mA per sensor, integrated mains unit max. 24 VDC, 25 W. In case of version 8/12 sensor inputs,
2 integrated mains units each max. 24 VDC, 25 W.
Interfaces: USB stick, Ethernet / RS 485 Modbus-RTU / TCP, SDI other bus systems on request, webserver optional
Outputs: • 4 relays (changeover contact 230 VAC, 6 A), alarm management, relays freely programmable, collective alarm
• Analog output, pulse in case of sensors with own signal output looped, such as e.g. VA/FA series
Memory card: Memory size 16 GB Micro SD card
Power supply: 100...240 VAC / 50-60 Hz, special version 24 VDC
Colour screen: 7" touch panel TFT transmissive, graphics, curves, statistics
Accuracy: see sensor specifications
Operating temperature: 0…50 °C
Storage temperature: -20…70 °C
Optional: Web server

Input Signals

Current signals
Internal or external
power supply
(0…20 mA/ 4…20 mA)
Measuring range 0…20 mA
Resolution 0.0001 mA
Accuracy ± 0.03 mA ± 0.05 %
Input resistance 50 Ω
Voltage signal (0…1 V)
Measuring range 0…1 V
Resolution 0.05 mV
Accuracy ± 0.2 mV ± 0.05 %
Input resistance 100 kΩ
Voltage signal (0...10 V / 30 V)
Measuring range 0…10 V
Resolution 0.5 mV
Accuracy ± 2 mV ± 0.05 %
Input resistance 1 MΩ
RTD Pt 100
Measuring range -200…850 °C
Resolution 0.1 °C
Accuracy ± 0.2 °C (-100…400 °C)
± 0.3 °C (further range)
RTD Pt 1000
Measuring rnage -200…850 °C
Resolution 0.1 °C
Accuracy ± 0.2° (-100…400 °C)
Pulse
Measuring range Min pulse length 500 μs
frequency 0...1 kHz
max. 30 VDC

DS 500 - Compressed air monitoring


From recording of the measured data, indication on a big colour screen, alerting, storage up to remote read-out via webserver... this is all possible with DS 500. The big difference to odinary paperless chart recorders reveals in the easy initiation and in the evaluation of the measured data. All sensors are identified directly and powered by DS 500. Everything is matched and tuned.

 


Which compressed air flow meter should be used at which point?

Flow meter types (in line, insertion, end user)

Free air delivery with differential pressure measurement for “wet air” (VD 500)

Thermal flow meters for consumption measurement (VA5XX)

Which benefits does a sophisticated flow measurement system offer?

Explanation of the measuring points


Intelligent chart recorder DS 500 for compressed air and gases


DS 500 - Intelligent chart recorder

From recording of the measured data, indication on a big colour screen, alerting, storage up to remote read-out via webserver... this is all possible with DS 500. By means of the CS Soft Basic software alarms can be sent via SMS or e-mail. All measured values, measured curves and threshold exceedings are indicated. The curve progressions from the beginning of the measurement can be viewed by an easy slide of the finger. Daily/weekly/monthly reports with costs in € and counter reading in m³ for each consumption sensor are completing the sophisticated system concept. The big difference to odinary paperless chart recorders reveals in the easy initiation and in the evaluation of the measured data. All sensors are identified directly and powered by DS 500. Everything is matched and tuned.


Advantages of DS 500 at a glance

  • Clear layout: 7" colour screen with touch panel
  • Versatile: Up to 12 optional sensors can be connected
  • Suitable for industrial applications: Metal housing IP 65 or panel mounting
  • Data avialable though world wide web: Network-compatible and remote transmission via webserver
  • Intelligent: Daily/weekly/monthly reports
  • Mathematical function for internal calculations
  • Totalizer function for analogue signals
  • Saves time and costs during installation


Mathematical function for internal calculations

e.g. the typical figures of a compressed air plant:

  • costs in € per generated m³ air
  • kwh/m³ generated air
  • consumption of single lines including summation


Totalizer function for analogue signals