Manufacturer:
The DS400 Mobile chart recorder with integrated data logger and up to 4 sensors connectable for energy analysis, flow measurement, leakage calculation of compressed air systems
Part Number: DS 400 Mobile
Back to Previous Page
Call for pricing

DS 400 mobile - Affordable mobile chart recorder 

with integrated data logger and up to 4 sensors connectable, including voltage supply for all sensors.


Your advantages of DS 400 mobile at a glance

  • Easy and clear layout: Very easy operation via 3.5" color display with touch panel
  • Versatile: Up to 4 sensors/meters connectable also third-party sensors/meters including power supply
  • Reliable: Stores all measured values on a memory card, easy reading out via USB stick possible
  • Intelligent energy analysis: Daily/weekly/monthly evaluations mathematic function for internal calculations, e.g. the typical key data of a compressed air plant


Software options

  • Integrated webserver
  • Mathematic calculation function
  • Totalizer function


Hardware options

  • Ethernet / RS 485 interface
  • Additional sensor inputs (digital or analogue)

Technical Data DS400 Mobile

Dimensions: 270 x 225 x 156 mm (W x H x D)
Weight: 2.2 kg
Inputs: 2 x 2 sensor inputs for digital or analogueue sensor signals
Interface: USB (standard), Ethernet (optional)
Power supply: Internal rechargeable Li-Ion batteries, approx 8 h continuos operation,
4 h charging time
Options:
Integrated data logger: 100 million measured values start/stop time, measuring rate freely
adjustable
2 additional sensor inputs: For connection of pressure sensors, temperature sensors, clampon
ammeters, third-party sensors with 4...20 mA, 0 to 10 V, Pt 100,
Pt 1000



Input Signals

Current signals
internal or external
power supply
(0…20 mA/4…20 mA)
Measuring range 0…20 mA
Resolution 0.0001 mA
Accuracy ± 0.03 mA ± 0.05 %
Input resistance 50 Ω
Voltage signal (0…1 V)
Measuring range 0…1 V
Resolution 0.05 mV
Accuracy ± 0.2 mV ± 0.05 %
Input resistance 100 kΩ
Voltage signal (0...10 V / 30 V)
Measuring range 0…10 V
Resolution 0.5 mV
Accuracy ± 2 mV ± 0.05 %
Input resistance 1 MΩ
RTD Pt 100
Measuring range -200…850 °C
Resolution 0.1 °C
Accuracy ± 0.2 °C (-100…
400 °C)
± 0.3 °C (further range)
RTD Pt 1000
Measuring range -200…850 °C
Resolution 0.1 °C
Accuracy ± 0.2° (-100…400 °C)
Pulse
Measuring range Min pulse length
500 µs frequency
0...1 kHz
max. 30 VDC

Which compressed air flow meter should be used at which point?


DS 400 mobile - Affordable mobile chart recorder 

with integrated data logger and up to 4 sensors connectable, including voltage supply for all sensors.


Your advantages of DS 400 mobile at a glance

  • Easy and clear layout: Very easy operation via 3.5" color display with touch panel
  • Versatile: Up to 4 sensors/meters connectable also third-party sensors/meters including power supply
  • Reliable: Stores all measured values on a memory card, easy reading out via USB stick possible
  • Intelligent energy analysis: Daily/weekly/monthly evaluations mathematic function for internal calculations, e.g. the typical key data of a compressed air plant


Software options

  • Integrated webserver
  • Mathematic calculation function
  • Totalizer function


Hardware options

  • Ethernet / RS 485 interface
  • Additional sensor inputs (digital or analogue)