The duct temperature transmitter TDTH is used for sensing the air temperature in heating, ventilation and air conditioning systems (e.g. in supply air, extract air or mixed air ducts).
Duct temperature transmitters TDTH have 8 different temperature ranges in same unit, selectable via jumpers on pcb:
- -20C to +150C,
- -50C to +50C,
- -20 to +80C,
- -30C to +60C,
- 0 to +40C,
- 0 to +50C, 0 to +100C and
- 0 to +150C.
Other temperature ranges on request.
Features
- Active transmitters 0-10 Vdc or 4-20 mA output
- With or without display
- 8 different temperature ranges in same unit,
- Standard probe length 200 mm On request 50, 100, 150, 250 or 300 mm probe lenghts
- IP65 enclosure with quick locking screws
- Supplied with duct mounting flange for good sealing into the duct.
The power supply for duct temperature transmitter TDTH with 4-20 mA output is 15-36 Vdc and the power supply for duct temperature transmitter TDTH with 0-10 Vdc output is 24 Vac/dc.
The active duct temperature transmitter TDTH with output 0-10 Vdc and 4-20 mA have a PT1000 sensor (DIN EN 60751, class B).
The sensing element for the duct temperature transmitter TDTH is located in the end of the probe.
Duct temperature transmitter TDTH have IP65 enclosure.
Wiring connection for duct temperature transmitter TDTH is inside the ABS plastic enclosure on a terminal block.
The enclosure of duct temperature transmitter TDTH is supplied with a plastic cable entry gland M 16 x 1.5, including strain relief.
TDTH duct temperature transmitter can be supplied with or without LCD display.
The probe of duct temperature transmitter TDTH is made of quality steel, standard probe length for the duct temperature transmitter TDHT is 200 mm, on request the duct temperature transmitter TDHT can be supplied with 50, 100, 150,, 250 and 300 mm probe lenghts.
Duct temperature transmitter TDTH is supplied with a duct mounting flange for fast and easy mounting and for good sealing into the duct.