Technical Information
|
Sensor
|
Temperature |
RH |
Measurement Range |
-40°C to 75°C (-40°F to 167°F) |
0–100% RH at -40° to 75°C (-40° to 167°F); exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1% |
Accuraqcy |
±0.25°C from -40° to 0°C (±0.45°F from -40° to 32°F) ±0.20°C from 0° to 70°C (±0.36°F from 32° to 158°F) ±0.25°C from 70° to 75°C (±0.45°F from 158° to 167°F) |
±2.5% from 10% to 90% RH typical to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical |
Resolution |
0.02°C (0.036°F) |
0.01% RH |
Drift |
<0.01°C (0.018°F) per year |
<1% per year typical |
Response Time (typical, to 90% of change) |
3 minutes, 45 seconds in air moving 1 m/s |
15 seconds in air moving 1 m/s |
Wireless Mote
|
Operating Temperature Range |
-40° to 70°C (-40° to 158°F) |
Radio Power |
12.6 mW (+11 dBm) non-adjustable |
Transmission Range |
Reliable connection to 457.2 m (1,500 ft) line of sight at 1.8 m (6 ft) high Reliable connection to 609.6 m (2,000 ft) line of sight at 3 m (10 ft) high |
Wireless Data Standard |
IEEE 802.15.4 |
Radio Operating Frequencies |
RXW-THC-B-900: 904–924 MHz RXW-THC-B-868: 866.5 MHz RXW-THC-B-921: 921 MHz RXW-THC-B-922: 916–924 MHz |
Modulation Employed |
OQPSK (Offset Quadrature Phase Shift Keying) |
Data Rate |
Up to 250 kbps, non-adjustable |
Duty Cycle |
<1% |
Maximum Number of Motes |
Up to 50 wireless sensors or 336 data channels per one HOBO RX station |
Logging Rate |
1 minute to 18 hours |
Number of Data Channels |
3 |
Battery Type |
Two AA 1.5 V lithium batteries |
Battery Life |
1 year, typical use |
Memory |
16 MB |
Dimensions |
Sensor: 45.97 x 11.43 x 10.16 mm (1.81 x 0.45 x 0.40 inches) Mote: 16.2 x 8.59 x 4.14 cm (6.38 x 3.38 x 1.63 inches) |
Weight |
223 g (7.87 oz) |
Materials |
Sensor: Polyamide Mote: PCPBT, silicone rubber seal |
Environmental Rating |
IP67, NEMA 6 |
Compliance Marks |
See User Manual |