Model
|
Description and Features
|
Download
|
2300-A8I |
8 x 4~20mA inputs, single ended (all input negatives internally connected) 0~20mA inputs programmable 250 ohms input resistance 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 30mA typical Requires an independent and isolated power supply to power logic inputs |
Installation Guide
Modbus supplementary manual
|
2300-A8II |
8 x 4~20mA inputs, Isolated 1.0KV isolation between each input 0~20mA inputs programmable 250 ohms input resistance 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 40mA typical |
Installation Guide
Modbus supplementary manual
|
2300-A8VI |
8 x Voltage inputs, Isolated 1.0KV isolation between each input 0~10V or 2~10V inputs programmable 20 Kohms input resistance 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 40mA typical |
Installation Guide
Modbus supplementary manual
|
2300-Tc8 |
8 x Thermocouple & mV inputs, Isolated 350V peak isolation between each input Programmable inputs type K, J, T, E, N, B, S, R, with CJC Programmable mV inputs 0~50mV, -100~100mV All inputs are set to the same type 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 40mA typical |
Installation Guide
Modbus supplementary manual
|
2300-RTD6 |
6 x RTD inputs, Pt100, Pt1000, Ni120, Ni1000 1.5KV isolation between inputs and power supply and comms (RS485) Resolution = 0.1°C Power Supply = 24Vdc @ 55mA typical |
Installation Guide
Modbus supplementary manual
|
2300-MULTI |
6 x combination analogue inputs, single ended 2 x RTD inputs, 2 x 4~20mA inputs, 2 x Voltage inputs, 1 x 4~20mA output, 4 x Digital inputs, 2 x Digital outputs 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 70mA typical |
Installation Guide
Modbus supplementary manual
|
2300-D16 |
16 x Digital inputs Input voltage: 12~24Vdc 1.5KV isolation between inputs and power supply and comms (RS485) Power Supply = 24Vdc @ 30mA typical |
Installation Guide
Modbus supplementary manual
|
2300-RO4 |
4 x Relay outputs Change over contacts Contact rating: 240Vac @ 0.5A 28Vdc @ 1A 1.0KV isolation between inputs and power supply and comms (RS485) One output can be dedicated to Comms Fail Alarm Power Supply = 24Vdc @ 100mA typical |
Installation Guide
Modbus supplementary manual
|
2300-AO8I |
8 x 4~20mA outputs, single ended (all output negatives internally connected) 0~20mA outputs programmable 1.5KV isolation between outputs and power supply and comms (RS485) Power Supply = 24Vdc @ 18mA typical Requires an independent and isolated power supply to power logic outputs = 24Vdc @ 175mA typical |
Modbus Manual |
|
24V DC Power Supply Options: |
PSW-2-F |
Output Voltage: 24Vdc Max current: 200mA continuous Input Power Supply: 85~265Vac/dc |
Installation Guide |
PSW-10-X |
Output Voltage: 24Vdc Max Current: 1 Amp continuous Input Power Supply: 100~264Vac/dc |
Installation Guide |
|
RS485 Comms Converter Options: |
2400-IS |
Isolated USB/RS232 to RS485 Converter. Comms baud rate: 9600 Powered Via Computer USB Port. |
Installation Guide |
2100-IS |
RS232 to RS485 Isolating converter. Comms baud rate: 9600 Relay output: 1 relay, change over. Rating, 1 amp, 24Vdc. Power supply: 9V plug pack (supplied with 2100-IS). Internal audible and relay output alarm for communication failure. |
Installation Guide |
2100-NS |
RS232 to RS485 converter kit. Non-isolating. Comms baud rate: 9600 Power supply: 9 volt plug pack (supplied with 2100-NS). |
Installation Guide |
2300-NET |
Ethernet TCP/IP to RS485 Converter. Isolating. Comms baud rate: 9600 Power supply: 24Vdc Modbus TCP to Modbus RTU Compact DIN rail mount Enclosure The PSW-2-X can be supplied with the 2300-NET if you require a 24Vdc Power supply. Note: For connecting via Ethernet, the 2300-NET is used with the 2300 series I/O Remote Stations. For the 2100 series I/O Remote Stations and Shimaden Controllers use the 2100-NET. |
Installation Guide
|