Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Search
Menu Close

Intech IN-uP4 - Universal Input Indicator

Manufacturer:
The IN-uP4 is a universal single input indicator, which makes interface with a wide range of sensors easy.
Part Number: IN-UP4
*
Back to Previous Page
Product Files
$390.00 ex GST
i h

Description:

The IN-uP4 is a universal single input indicator, which makes interface with a wide range of sensors easy.
The IN-uP4 has a 4-digit LED display. An option to add two relay outputs (with two setpoint indicator LED’s), and one 4~20mA analogue output is available. The indicator (Rev 1) has a Universal Power Supply of 24~250Vac / 19.5~250Vdc.
Setup and calibration is simple, using ‘uP Configure’ software, with step-by-step instructions.

Features:

  • Universal Input with Indication.
  • Panel Mount.
  • Programmable via USB Port using uP Configure software and XU-USB (Rev 1) key.
  • Simple setup and calibration.
  • 4-digit LED Display.
  • Option to add Two Relay Outputs (with two setpoint indicator LED’s), and One 4~20mA Analogue Output.
  • Universal Power Supply of 24~250Vac / 19.5~250Vdc.
  • Sensor Power Supply for powering external Transmitter.
  • IP65.

Ordering Information:

Code Description
IN-uP4   Universal Input Indicator with No Outputs.
IN-uP4X   Universal Input Indicator with Two Relay Outputs plus One 4~20mA Analogue Output.

Universal Power Supply of 24~250Vac / 19.5~250Vdc.

Note: The IN-uP4 Universal Input Indicator is pre-programmed for RTD Pt100 input as standard.

To program the IN-uP4 requires the XU-USB (Rev 1) Programming Key:

XU-USB (Rev 1)

USB Programming Key for programming IN-uP4 using uP Configure Programming Software (version 1.5.7 or later).
Note: XU-USB must be (Rev 1) or later! Older versions will NOT connect with the IN-uP4.

(Same Key as used for programming XU Series transmitters, 2400-A16 / 2400-M-R, Z-2400-Sleeper, Z-2400-A2 Series 
and uP4-Din.)

 

Input Specifications:
 Excitation - Sensor Power Supply +22Vdc ±10%, 25mA max.
    Accuracy/Repeatability 0.05% of FSO.
    Temperature Drift 30ppm/°C typical.
 Voltage Input Specifications:
    mV Range -200mV~200mV.
    V Range 0~1V, 0~10V, -10~30V, 0~300V.
    Minimum Input resistance 1MΩ.
    Linearity and Repeatability <±0.02% FSO typical.
    Response Time 100msec.
    USB Programmable Zero 0~±99% of the Span.
   USB Programmable Span 95% of FSO.
Current Input Specifications:
    mA Range 0~20mA (4~20mA).
    Input Resistance 10Ω.
    Maximum Over-range 50mAdc Continuous.
    Linearity and Repeatability <±0.02% FSO typical.
    Response Time 100msec.
    USB Programmable Zero 0~±99% of the Span.
    USB Programmable Span 1µA~24mAdc.
Thermocouple Input Specifications:
    Thermocouple Types B, E, J, K, N, R, S, T.
    Input Impedance 1MΩ Minimum.
    T/C Lead Resistance 100Ω Maximum.
    Cold Junction Compensation -10~70°C.
    Accuracy E, J, K, N, T <±1°C.

B, R, S <±2°C.
    Temperature Drift E, J, K, N, T <±0.05°C.
B, R, S <±0.2°C.
CJC Error <±2°C.
    Sensor Fail Upscale or Downscale Selectable (Upscale Default).
    Response Time 400msec.
    USB Programmable Zero 0~±99% of the Span.
    USB Programmable Span Within Thermocouple Type limits.
RTD Input Specifications:
    RTD Input Pt100 or Pt1000 DIN 3-wire Type.
(2-wire can be used with offset calibration.)
    Sensor Current 0.3mA Nominal.
    Lead Wire Resistance Pt100: 10Ω/wire Maximum.
Pt1000: 5Ω/wire Maximum.
0.02% FSO Offset Error per Ω of Lead Resistance.
Sensor Fail Upscale or Downscale Selectable (Upscale Default).
    Linearity (Pt100) 0.02% FSO for Span Inputs ≤200°C. 0.1% FSO for Span Inputs ≤300°C.
    Linearity (Pt1000) 0.02% FSO for Span Inputs ≤200°C. 0.2% FSO for Span Inputs ≤300°C.
    Response Time 400msec.
    USB Programmable Zero 0~±99% of the Span.
    USB Programmable Span Within Thermocouple Type limits.
NTC Thermistor Input Specifications:
    NTC Sensor Types 10K (Beta 3984)   -55~125°C.
10K (Beta 3435)   -50~110°C.
    Response Time 100msec.
Pulse & Frequency Input Specifications:
    Input Type Open Contact: NPN, 24Vdc Max.
PNP, 5Vdc Max.
    Frequency Range 0~2000Hz.
    Response Time 100msec.
    Software Modes General Frequency, Flow Rate or RPM.
Potentiometer Input Specifications:
    Potentiometer input 3-wire.
    Excitation voltage Variable.
    Field programmable zero 0~90% of span.
    Potentiometer resistance <1kΩ low pot; 1~4kΩ med pot; 4~20kΩ high pot.
    Field programmable span 0.1~100%.
    Linearity and repeatability <±0.05% FSO typical.
    Response time 100msec.
Output Specifications: IN-uP4X only.
    Analogue Output: Isolated.
        mA Range 4~20mA or 20~4mA.
        Resolution 1µA.
        Output Drive 600Ω at 12Vdc.
    Relay Outputs: 2 Isolated Relays with LED indication on each output.
        Functions 2 on Board Controllers can be used as Set Point (SV), Switching Differential,
Auto/Manual, Manual Output Setting, Dual Action Control, Single Action Control,
Heat/Cool, Cool Only, Heat Only.
        Relay Ratings 250Vac, 3A Max.
General Specifications:
    Power Supply: 24~250Vac / 19.5~250Vdc (47-63Hz, 6VA max).
    Safety Compliance:
        EMC Emissions EN 61326.
        EMC Immunity EN 61326.
        Safety EN 61010-1.
    General Specifications:
        Accurate to <±0.03% FSO typical.
        Ambient drift <±0.003%/°C FSO typical.
        EMC Influence <0.2% of full scale range.
        Noise Immunity 125dB CMRR average (2.0KVdc limit).
        Operating Humidity 5~85%RH max (non-condensing).
        Operating Temperature -10~50°C.
        Storage Temperature -20~60°C.
        Indicator Housing: IP65.
            Dimensions H=48mm, W=95mm, D=84mm.
Allow 80mm minimum behind panel for connectors and wiring.
            Panel Cutout H=45mm, W=92mm.

Setup and calibration is simple, using ‘uP Configure’ software (version 1.5.23 or later), with step-by-step instructions.

Download uP Configure Software here

Description:

The IN-uP4 is a universal single input indicator, which makes interface with a wide range of sensors easy.
The IN-uP4 has a 4-digit LED display. An option to add two relay outputs (with two setpoint indicator LED’s), and one 4~20mA analogue output is available. The indicator (Rev 1) has a Universal Power Supply of 24~250Vac / 19.5~250Vdc.
Setup and calibration is simple, using ‘uP Configure’ software, with step-by-step instructions.

Features:

  • Universal Input with Indication.
  • Panel Mount.
  • Programmable via USB Port using uP Configure software and XU-USB (Rev 1) key.
  • Simple setup and calibration.
  • 4-digit LED Display.
  • Option to add Two Relay Outputs (with two setpoint indicator LED’s), and One 4~20mA Analogue Output.
  • Universal Power Supply of 24~250Vac / 19.5~250Vdc.
  • Sensor Power Supply for powering external Transmitter.
  • IP65.

Ordering Information:

Code Description
IN-uP4   Universal Input Indicator with No Outputs.
IN-uP4X   Universal Input Indicator with Two Relay Outputs plus One 4~20mA Analogue Output.

Universal Power Supply of 24~250Vac / 19.5~250Vdc.

Note: The IN-uP4 Universal Input Indicator is pre-programmed for RTD Pt100 input as standard.

To program the IN-uP4 requires the XU-USB (Rev 1) Programming Key:

XU-USB (Rev 1)

USB Programming Key for programming IN-uP4 using uP Configure Programming Software (version 1.5.7 or later).
Note: XU-USB must be (Rev 1) or later! Older versions will NOT connect with the IN-uP4.

(Same Key as used for programming XU Series transmitters, 2400-A16 / 2400-M-R, Z-2400-Sleeper, Z-2400-A2 Series 
and uP4-Din.)