Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Search
Menu Close

Jumo tecLine H2O2 and PAA hydrogen peroxide and peracetic acid sensor

Manufacturer:
The membrane-covered, amperometric sensors measure the concentration of hydrogen peroxide or peracetic acid in aqueous solutions. Typical application areas include electroplating plants, dairies, swimming pools, and the chemicals industry.
Part Number: 202636
Back to Previous Page
Call for pricing

Monitor hydrogen peroxide and peracetic acid concentrations easily 

The membrane-covered, amperometric sensors measure the concentration of hydrogen peroxide or peracetic acid in aqueous solutions. Typical application areas include electroplating plants, dairies, swimming pools, and the chemicals industry.

The sensors are not suitable for detecting the absence of peracetic acid or hydrogen peroxide.

Depending on the type, the electronics integrated in the sensors provide a temperature-compensated
current signal (4 to 20 mA) or a Modbus RTU output signal.

The sensors can be connected directly to indicating devices/transmitters/controllers. They supply the sensors with voltage and allow for easy calibration of the measuring system.


Features

  • Detection of peracetic acid or hydrogen peroxide concentration in the mg range
  • 2-electrodes principle
  • Chemical- and surfactant-resistant membrane
  • Easy calibration
  • Integrated temperature compensation
  • Proven measuring system
  • Electrical connection analog or digital

Technical Information

Measuring Range Hydrogen peroxide: max. 0.05 to 20000 mg/l (analog), max. 0.05 to 200000 mg/l (digital); peracetic acid: 0.05 to 20000 mg/l (analog and digital)
Measuring Principle Membrane-covered, amperometric two-electrode system with integrated electronic components
Inflow Speed Approx. 15 cm/s
Response Time Hydrogen peroxide: approx. 5 to 10 minutes; peracetic acid: approx. 5 minutes at 10 °C
Operating Temperature 0 to 45 °C
Settling Time Hydrogen peroxide: approx. 3 hrs for initial startup; peracetic acid: approx. 1 hr for initial startup
pH Value Area of Applications Hydrogen peroxide: pH 2 to pH 11; peracetic acid: pH 1 to pH 6
Applications Areas Drinking water, swimming pool water, service water

Monitor hydrogen peroxide and peracetic acid concentrations easily 

The membrane-covered, amperometric sensors measure the concentration of hydrogen peroxide or peracetic acid in aqueous solutions. Typical application areas include electroplating plants, dairies, swimming pools, and the chemicals industry.

The sensors are not suitable for detecting the absence of peracetic acid or hydrogen peroxide.

Depending on the type, the electronics integrated in the sensors provide a temperature-compensated
current signal (4 to 20 mA) or a Modbus RTU output signal.

The sensors can be connected directly to indicating devices/transmitters/controllers. They supply the sensors with voltage and allow for easy calibration of the measuring system.


Features

  • Detection of peracetic acid or hydrogen peroxide concentration in the mg range
  • 2-electrodes principle
  • Chemical- and surfactant-resistant membrane
  • Easy calibration
  • Integrated temperature compensation
  • Proven measuring system
  • Electrical connection analog or digital