Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Holiday Closure: We will be closed from Mon, 23rd Dec & will return on Thurs, 2nd Jan 2025

Search
Menu Close

Monnit Enterprise Carbon Dioxide (CO2) Wireless Sensor

Manufacturer:
This sensor monitors Carbon Dioxide (CO2) gas; if levels exceed preset limits, designated personnel are alerted via text, email, or call
Part Number: MNS2-4-W2-GS-C2
Back to Previous Page
$915.00 ex GST
i h
Delivery date: 2-3 weeks

Protect employee wellness & productivity

As Carbon Dioxide (CO2) concentrations rise within facilities, occupants may suffer from fatigue; excessive exposure triggers nausea and/or vomiting. Monnit’s Enterprise Carbon Dioxide Wireless Sensor monitors this gas; if levels exceed preset limits, designated personnel are alerted via text, email, or call.

The Wireless Carbon Dioxide Sensor uses an ultra low-power, high-performance CO2 sensor to measure the amount of carbon dioxide in ambient air. It is programmed to take readings at a set interval to accurately calculate CO2 levels, then send the time-stamped data to the iMonnit Online Sensor Monitoring and Notification System at user-specified time intervals (sensor heartbeat). The CO2 data can be reviewed and exported as a data sheet or graph and notifications can be set up through the online system to alert the user when defined thresholds have been met or exceeded.


Sensor features:

  • Measures 0–10000 ppm
  • AA-battery powered (10+ year battery life)
  • Instantaneous CO2 readings & 8-hour, time-weighted average readings
  • Options: on/off switch or line-power with battery backup and on/off switch


Additional features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Indoor air quality
  • Marine Vessels
  • Grow houses
  • Ventilation Management
  • Cellar and gas stores
  • Modified atmospheres
  • Confined spaces


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.


Monnit Gateway Options

An integral component of any IoT network is the gateway. A gateway device allows for data from sensors to be transmitted to the iMonnit software platform.


Monnit Ethernet Wireless Gateway 4

Monnit’s Ethernet Gateways allow your Monnit Wireless Sensors to communicate with the iMonnit™ Online Wireless Sensor Monitoring and Notification System without the need for a PC. Simply provide power and plug the gateway into an open Ethernet network port with an internet connection. It will then automatically connect with our online servers, providing the perfect solution for commercial locations where there is an active internet connection.

Learn more about the Ethernet Wireless Gateway 4>>



Monnit 4G + Ethernet IoT Gateway

The ALTA® by Monnit Wireless IoT Gateway combines a 4G LTE CAT-M1/NB2 cellular engine and Ethernet platform with Monnit’s wireless access point network to aggregate and communicate data from Monnit ALTA Wireless Sensors. The ALTA IoT Gateway allows ALTA Sensors to operate on the world’s leading cellular networks and stay connected to the Internet. The gateway uses AC main power but also has redundant power through a battery backup lasting up to 60 hours.

To meet the global demand for enterprise IoT deployment, the IoT Gateway communicates with the cloud-based iMonnit® monitoring software via cellular transmission, making it ideal for remote locations or where the Internet isn’t available. The RJ-45 Ethernet jack allows local device configuration, diagnostics, and connectivity backup. The IoT Gateway is instrumental in sending sensor notifications via text, email, or call if user-defined conditions are met or exceeded.

Learn more about the 4G + Ethernet Wireless Gateway 4>>


Online Sensor Monitoring Software

iMonnit is a cloud based mobile internet platform and central hub for managing Monnit and ALTA products. All data is secured on dedicated servers operating Microsoft SQL Server. This online user interface is where all your device settings can be arranged, supervised, and modified to reflect your unique environment. OneTemp will look after the activation and setup of your new online iMonnit account free of charge. There is also a free mobile app for you to stay in control at all times. Start with the basic version or upgrade to iMonnit Premiere to enjoy the full features your Monnit experience can offer.


iMonnit Basic Vs Premiere:

  • Basic - Free with no ongoing costs
    Monnit Basic is included for free with all wireless sensors, providing basic features for you to configure and monitor your sensors online. These basic features only support one network and one registered user on an account.
  • Premiere - Minimal Annual Fee
    iMonnit Premiere allows for enhanced functionality of your wireless sensors and includes an advanced software feature set at a low annual cost. All of iMonnit's advanced features are availble for configuration. You can have more sensors on your account, support multiple users, and view floorplans for all your sensors.

Learn more about the iMonnit Premier Online Software>>

 


Technical Information

Supply voltage 2.0-3.8 VDC (3.0-3.8 VDC using power supply) *
Current consumption 0.2 μA (sleep mode)
0.7 μA (RTC sleep)
570 μA (MCU Idle)
2.5 mA (MCU Active)
5.5 mA (Radio RX Mode)
22.6 mA (Radio TX Mode)
Operating temperature range
(sensor and CO2 element)
0°C to 50°C (32°F to 122°F) standard range
Operating humidity range
(sensor and CO2 element)
0% to 95% (non-condensing)
Recommended storage temperature (no batteries) -30°C to +70°C (-22°F to +158°F)
Sensing method Non-dispersive infrared (NDIR) absorption
Gold-plated optics
Solid-state source and detector
Sample method Diffusion
Measurement range 0 to 10000 ppm CO2
Accuracy +/-( (45 ppm + 3%) * (1 + .0013 * ΔP)) **
Calibration Autocalibration **
Non linearity < 1% of FS
Pressure dependence 0.13% of reading per mm Hg in normal atmospheric conditions
Response time 3 minutes
Integrated memory Up to 3200 sensor messages
Wireless range 1,200+ ft non-line-of-sight
Security Encrypt-RF® (256-bit key exchange and AES-128 CTR)
Weight 4.5 ounces
Certifications 900 MHz product; FCC ID: ZTL-G2SC1 and IC:9794A-G2SC1.
868 and 433 MHz product tested and found to comply with: EN
300 220-2 V3.1.1


* Please take care when connecting a power device.

** ΔP is in mbar and is the difference between atmospheric pressure at sea level (1013 mbar) and the pressure at the sensors altitude (Ex: 1013
mbar - ambient pressure in mbar).

*** For correct autocalibration, the sensor must experience fresh air CO2 levels (~400 ppm) for at least 4 hours per day. If the environment does
not meet this criteria then disable the autocalibration feature.

Protect employee wellness & productivity

As Carbon Dioxide (CO2) concentrations rise within facilities, occupants may suffer from fatigue; excessive exposure triggers nausea and/or vomiting. Monnit’s Enterprise Carbon Dioxide Wireless Sensor monitors this gas; if levels exceed preset limits, designated personnel are alerted via text, email, or call.

The Wireless Carbon Dioxide Sensor uses an ultra low-power, high-performance CO2 sensor to measure the amount of carbon dioxide in ambient air. It is programmed to take readings at a set interval to accurately calculate CO2 levels, then send the time-stamped data to the iMonnit Online Sensor Monitoring and Notification System at user-specified time intervals (sensor heartbeat). The CO2 data can be reviewed and exported as a data sheet or graph and notifications can be set up through the online system to alert the user when defined thresholds have been met or exceeded.


Sensor features:

  • Measures 0–10000 ppm
  • AA-battery powered (10+ year battery life)
  • Instantaneous CO2 readings & 8-hour, time-weighted average readings
  • Options: on/off switch or line-power with battery backup and on/off switch


Additional features

  • Impressive wireless range of up to 1,200 feet through walls
  • Frequency-hopping spread spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange + AES-128 CBC for sensor data messages)
  • Stores 2000 to 4000 readings if gateway connection is lost (non-volatile flash, persists through the power cycle)
    • 10-minute heartbeats = ~ 22 days
    • 2-hour heartbeats = ~ 266 days
  • Over-the-air updates
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Applications

  • Indoor air quality
  • Marine Vessels
  • Grow houses
  • Ventilation Management
  • Cellar and gas stores
  • Modified atmospheres
  • Confined spaces


IMPORTANT - Sensor Operation

Please note: this sensor requires both an applicable Gateway and iMonnit software to operate. For further information, please refer to the tabs above or related products below.