Search
Menu Close

Monnit Carbon Dioxide (CO2) Monitoring Solution

Manufacturer:
CO2 concentration provides insight into facility ventilation quality and HVAC calibration. Greenhouses and modern grow spaces also rely on CO2 sensor data to optimize crop growth. Maintain wellness and productivity with the Monnit Wireless CO2 Sensor below.
*
*
*
*
Back to Previous Page
$0.00 ex GST
i h
Delivery date: 2-3 weeks

As Carbon Dioxide (CO2) concentrations rise within facilities, occupants may suffer from fatigue; excessive exposure triggers nausea and/or vomiting. Monnit’s ALTA® CO2 sensor monitors this gas; if levels exceed preset limits, designated personnel are alerted via text, email, or call.

This kit gives you a simple solution to monitor your assets 24/7 with no complicated wiring or setup.


The C02 Monitoring Kit Contains:

  • 1 x ALTA Ethernet or 4G Gateway* 
  • Wireless CO2 Sensors 
  • 12 Months Subscription to iMonnit web based online software
  • Optional x Notification Credits for SMS Alarm Notifications (2 credits per SMS)
  • Mounting Hardware
  • 2 x AA Batteries
  • Free delivery to anywhere in Australia

*Optional 4G Gateway Upgrade includes 1 x ALTA 4G Gateway and SIM Plan for 12 Months (Learn More)

Adding more sensors is extremely simple and can be done at any time. These include not only C02, but a large selection for almost everything you wish to monitor such as Humidity, Water Detection, Motion, AC Current, etc. See our sensors HERE

The system is supplied fully configured and ready to go, just place the sensors in your area to be monitored and plug in the Gateway. (Ethernet DHCP plug and play, or configured for advanced networks by your IT)


Sensor features:

  • Measures 0–10000 ppm
  • AA-battery powered (10+ year battery life)
  • Instantaneous CO2 readings & 8-hour, time-weighted average readings
  • Options: on/off switch or line-power with battery backup and on/off switch


The ALTA Wireless Carbon Dioxide Sensor measures the amount of CO2 in the ambient air surrounding the element. It is programmed to take readings at a set interval to accurately calculate CO2 levels, then send the time-stamped data to the iMonnit Online Sensor Monitoring and Notification System at user-specified time intervals (sensor heartbeat). The CO2 data can be reviewed and exported as a data sheet or graph and notifications can be set up through the online system to alert the user when defined thresholds have been met or exceeded.


Features of Monnit ALTA Sensors

  • Wireless range of 1,200+ feet through 12+ walls *
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life **
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange
    • + AES-128 CBC for sensor data messages)
  • All ALTA sensors now have up to 3200 readings:
    • 10-minute heartbeats = 22 days
    • 2-hour heartbeats = 266 days
  • Over-the-air updates (future proof)
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Important Notes:

  • iMonnit Portal Plan included in this system is for 12 months from day of purchase and up to a maximum of 6 sensors. At the end of the plan you can switch to iMonnit basic which is a free plan or continue with premium for a small 12 monthly fee.
  • SMS credits are sold in a pack of 100 credits, each SMS in Australia and NZ is at a cost of 2 credits, (50 SMS's per pack). The system can be set to notify you when credits reach a desired low level and purchasing another pack can be done through OneTemp.
  • The 4G Gateway is supplied with a SIM card fitted and activated on the Telstra Mobile network (Aust) and Spark (NZ) for 12 months. A reminder will be sent to you on the iMonnit account administrators email address at 11 months for renewing this plan for a further 12 months.

ALTA - Leading Enterprise Grade "Internet of Things" Solutions

ALTA sensors offer 3 to 4 times the range of standard sensor platforms, extending non-line-of-sight reach to an exceptional 1,200+ feet through walls (12-14 walls typical). Using Frequency-hopping Spread Spectrum (FHSS) also allows ALTA sensors to have better interference immunity from other wireless devices.Superior power management provides ALTA sensors with almost twice the battery life of Monnit’s standard wireless sensors.

  • Coin cell sensors typically last 3+ years.
  • AA and Industrial sensors typically last up to 12+ years.

ALTA products employ Monnit's new Encrypt-RF® Security (256-bit Diffie Hellman key exchange and AES-128 CBC encryption for all sensor data messages), so security is maintained at all communication points from sensor to gateway, gateway to software, then back again.

Integrated on-board data storage allows ALTA sensors to store data messages if communication to a wireless gateway is disrupted (power outage, Internet outage, or out of range). Messages that can’t be delivered will be time-stamped and stored in memory (up to the last 512 messages) until communication with the gateway is restored, at which point the messages will all be transmitted.Over-the-air updates allow ALTA products to be updated remotely if new fixes or features become available.The standard version of this sensor is powered by two replaceable 1.5 V AA sized batteries (included with purchase). This sensor is also available with a line power option. The line powered version of this sensor has a barrel power connector allowing it to be powered by a standard 3.0 - 3.8 V power supply (Included with Line Power option upgrade). The line powered version also uses two standard 1.5 V AA batteries as backup for uninterrupted operation in the event of line power outage.Power options must be selected at time of purchase, as the internal hardware of the sensor must be changed to support the selected power requirements.


Technical Information


As Carbon Dioxide (CO2) concentrations rise within facilities, occupants may suffer from fatigue; excessive exposure triggers nausea and/or vomiting. Monnit’s ALTA® CO2 sensor monitors this gas; if levels exceed preset limits, designated personnel are alerted via text, email, or call.

This kit gives you a simple solution to monitor your assets 24/7 with no complicated wiring or setup.


The C02 Monitoring Kit Contains:

  • 1 x ALTA Ethernet or 4G Gateway* 
  • Wireless CO2 Sensors 
  • 12 Months Subscription to iMonnit web based online software
  • Optional x Notification Credits for SMS Alarm Notifications (2 credits per SMS)
  • Mounting Hardware
  • 2 x AA Batteries
  • Free delivery to anywhere in Australia

*Optional 4G Gateway Upgrade includes 1 x ALTA 4G Gateway and SIM Plan for 12 Months (Learn More)

Adding more sensors is extremely simple and can be done at any time. These include not only C02, but a large selection for almost everything you wish to monitor such as Humidity, Water Detection, Motion, AC Current, etc. See our sensors HERE

The system is supplied fully configured and ready to go, just place the sensors in your area to be monitored and plug in the Gateway. (Ethernet DHCP plug and play, or configured for advanced networks by your IT)


Sensor features:

  • Measures 0–10000 ppm
  • AA-battery powered (10+ year battery life)
  • Instantaneous CO2 readings & 8-hour, time-weighted average readings
  • Options: on/off switch or line-power with battery backup and on/off switch


The ALTA Wireless Carbon Dioxide Sensor measures the amount of CO2 in the ambient air surrounding the element. It is programmed to take readings at a set interval to accurately calculate CO2 levels, then send the time-stamped data to the iMonnit Online Sensor Monitoring and Notification System at user-specified time intervals (sensor heartbeat). The CO2 data can be reviewed and exported as a data sheet or graph and notifications can be set up through the online system to alert the user when defined thresholds have been met or exceeded.


Features of Monnit ALTA Sensors

  • Wireless range of 1,200+ feet through 12+ walls *
  • Frequency-Hopping Spread Spectrum (FHSS)
  • Improved interference immunity
  • Improved power management for longer battery life **
  • Encrypt-RF® Security (Diffie-Hellman Key Exchange
    • + AES-128 CBC for sensor data messages)
  • All ALTA sensors now have up to 3200 readings:
    • 10-minute heartbeats = 22 days
    • 2-hour heartbeats = 266 days
  • Over-the-air updates (future proof)
  • Free iMonnit basic online wireless sensor monitoring and notification system to configure sensors, view data and set alerts via SMS text and email


Important Notes:

  • iMonnit Portal Plan included in this system is for 12 months from day of purchase and up to a maximum of 6 sensors. At the end of the plan you can switch to iMonnit basic which is a free plan or continue with premium for a small 12 monthly fee.
  • SMS credits are sold in a pack of 100 credits, each SMS in Australia and NZ is at a cost of 2 credits, (50 SMS's per pack). The system can be set to notify you when credits reach a desired low level and purchasing another pack can be done through OneTemp.
  • The 4G Gateway is supplied with a SIM card fitted and activated on the Telstra Mobile network (Aust) and Spark (NZ) for 12 months. A reminder will be sent to you on the iMonnit account administrators email address at 11 months for renewing this plan for a further 12 months.